21
YASKAWA AC Drive CR700 Catalog
|
KAEP C710617 24
|
YASKA WA
400 V Class
*
1
:
For the most appropriate selection, contact your Yaskawa or nearest sales representative.
*
2
:
The value displayed is the input current when operating standard Yaskawa motors at the maximum applicable capacity with the rated load at the
rated motor speed. This value may uctuate based on the power supply side impedance, as well as the input current, power supply transformer,
input side reactor, and wiring conditions.
*
3
:
Rated input capacity is calculated with a power line voltage of
480 V.
Catalog Code CR70A4 002 003 005 006 007 009 015 018 024 031 039 045 060 075 091
Max. Applicable
Motor Capacity
*
1
kW 0.40.75 1.52.233.75.57.5111518.522303745
Input
Rated Input
Current
*
2
A 1.93.54.76.78.911.715.821.230.641.350.543.158.371.586.5
Output
Rated Output
Current
A 1.83.44.85.57.29.214.81824313945607591
Overload Tolerance
150% of rated output current for 60 s
Note
:
Derating may be required for applications that start and stop frequently.
Carrier Frequency
Derating the output current enables a maximum of
15 kHz to be set.
(
Derating the output current is not necessary up to
8 kHz.
)
Max. Output
Voltage
Three
-
phase 380 to 480 V
Note
:
The maximum output voltage is proportional to the input voltage.
Max. Output
Frequency
590 Hz
The frequencies that can be set vary depending on the control mode used.
Measures for
Harmonics
DC Reactor External options Built
-
in
Braking
Function
Braking Transistor Built
-
in
EMC lter
EMC lter
EN
61800
-
3, C2/C3
Internal
(
factory option
)
Power
Rated Voltage /
Rated Frequency
・
Three
-
phase AC power supply 380 V to 480 V 50/60 Hz
・
DC power supply 513 V to 679 V
Allowable Voltage
Fluctuation
−
15
% to
10
%
Allowable
Frequency
Fluctuation
±
5
%
Power
Supply
*
3
kVA 1.52.83.75.37.19.3131724334034465769
Catalog Code CR70A4 112 150 180 216 260 304 371 414 453 605
Max. Applicable
Motor Capacity
*
1
kW 55 75 90 110 132 160 200 220 250 315
Input
Rated Input
Current
*
2
A 105 142 170 207 248 300 373 410 465 584
Output
Rated Output
Current
A 112 150 180 216 260 304 371 414 453 605
Overload Tolerance
150% of rated output current for 60 s
Note
:
Derating may be required for applications that start and stop frequently.
Carrier Frequency
Derating the output current enables a maximum of
10 kHz to
be set.
(
Derating the output current is not necessary up to
5 kHz.
)
Derating the output current enables a
maximum of
5 kHz to be set.
(
Derating the output current is not
necessary up to
2 kHz.
)
Max. Output
Voltage
Three
-
phase 380 to 480 V
Note
:
The maximum output voltage is proportional to the input voltage.
Max. Output
Frequency
590 Hz
The frequencies that can be set vary depending on the control mode used.
Measures for
Harmonics
DC Reactor Built
-
in
Braking
Function
Braking Transistor Built
-
in External options
EMC lter
EMC lter
EN
61800
-
3, C2/C3
Internal
(
factory option
)
Power
Rated Voltage /
Rated Frequency
・
Three
-
phase AC power supply 380 V to 480 V 50/60 Hz
・
DC power supply 513 V to 679 V
Allowable Voltage
Fluctuation
−
15
% to
10
%
Allowable
Frequency
Fluctuation
±
5
%
Power
Supply
*
3
kVA 84 113 136 165 198 239 297 327 370 465
Features
Catalog Code /
Selecting the Capacity
Basic
Instructions
Standard
Speci cations
Standard
Connection Diagram
Terminal
Speci cations
Dimensions
Fully
-
Enclosed
Design
Peripheral Devices
and Options
Application
Notes
Global Service
Network
Standard
Speci cations