YASKAWA AC Drive CR700 Catalog
KAEP C710617 24
YASKA WA
Note
:
1. Perform Rotational Auto
-
Tuning to achieve speci cations listed for Open Loop Vector Control, Close Loop Vector Control and Advanced Open Loop
Vector Control.
2. Install the drive in an environment matching the speci cations in the table above for optimum performance life.
*
Altitudes over 1000 m and up to 3000 m are possible by derating the output current by 1% for every 100 m.
Contact Yaskawa or your nearest sales representative for details.
Item Speci cations
Environment
Area of Use
Indoors
chemical gas
:
IEC 60721
-
3
-
3
:
3 C2
solid particle
:
IEC 60721
-
3
-
3
:
3 S2
Power Supply Overcurrent Category
III
Ambient Temperature
Open chassis type
(
IP
20
):
-
10
˚C
to +50
˚C
Enclosed wall
-
mounted type
(
UL Type 1
):
10
˚C
to
+
40
˚C
Do not use the drive in a location where the temperature changes suddenly to improve the drive reliability.
When installing the drive in an enclosure, use a cooling fan or air conditioner to keep the internal air temperature in
the permitted range.
Do not let the drive freeze.
Derate the output current and output voltage to install the drive in areas with ambient temperatures
60
˚C
.
Humidity
95% RH or less
(
no condensation
)
Storage Temperature
Short-term temperature during transportation is -
20
˚C to
+
70
˚C
Surrounding Area
Pollution degree 2 or less
Install the drive in an area without
:
Oil mist, corrosive or  ammable gas, or dust
Metal powder, oil, water, or other unwanted materials
Radioactive materials or  ammable materials, including wood
Harmful gas or  uids
Salt
Direct sunlight
Keep wood or other  ammable materials away from the drive.
Altitude
1000 m or less
*
Shock
10 Hz to 20 Hz, 1 G
(
9.8 m/s
2
)
20 Hz to 55 Hz, Catalog code CR70 2003 to 2180, 4002 to 4150
:
0.6 G
(
5.9 m/s
2
)
,
Catalog code CR
70 2215 to 2415, 4180 to 4605
:
0.2 G
(
2.0 m/s
2
)
Standards Compliance
UL61800
-
5
-
1
EN61800
-
3
:
2004+A1
:
2012
IEC/EN61800
-
5
-
1
Two Safe Disable inputs and 1EDM output according to ISO/EN13849
-
1 Cat.3 Ple
IEC/EN61508 SIL3
Note
:
Used by setting functions to multi
-
function digital output terminals.
Protection Design
Open chassis type
(
IP
20
)
, Enclosure wall
-
mounted type
(
UL Type 1
)
Note
:
Installing the UL Type
1 kit to a drive in an open chassis type
(
IP20
)
makes the drive compliant with an
enclosure wall
-
mounted type
(
UL Type 1
)
.
Features
Catalog Code /
Selecting the Capacity
Basic
Instructions
Standard
Speci cations
Standard
Connection Diagram
Terminal
Speci cations
Dimensions
Fully
-
Enclosed
Design
Peripheral Devices
and Options
Application
Notes
Global Service
Network
Standard
Speci cations

Other manuals for YASKAWA CR700

Related product manuals