(5) Line PG (external PG) switching FLPG3
i Servopack
LINE PG
(REF.) . (EXTERNAL PG)
(FB)
, " [ (SPEED}..=_._"..... 3CN) _, (ENCODER)MOTOR PG
LPG [ f__....... 4CN)
(5CN)[
When LPG signal is turned on, position feedback signal is switched from motor PG to
line PG and position fully closed loop by line PG is formed.
Line PG output pulse corresponds to reference data one-by-one. That is, one pulse
from line PG is read-in as one reference unit move.
When line PG is used, zero-point return (homing) cannot be performed. Entering
zero-point return mode causes an error.
(6) Input signal used in station No. reference method
(a) Rotating direction selection I-DRO,DR1]
By combining DROand DR1 signals, the rotating direction at the motor shaft
(viewed from the load side) in automatic operation mode is selected as shown
below:
p_na I DR0 H L H L
ter 14-b3N',_ DRI H H L L "
Absolute Short-cut Station No. Station No. (This setting
0 mode direction increasing decreasing causes an error.)
direction direction
(Example) (Example)
0 0
Incremental (This setting _"_-' _"_-'
1 mode causesan . , 3 ',
error.) k
-- 111 --