(5) Line PG (external PG) switching FLPG3
i Servopack
LINE PG
(REF.) . (EXTERNAL PG)
(FB)
, " [ (SPEED}..=_._"..... 3CN) _, (ENCODER)MOTOR PG
LPG [ f__....... 4CN)
(5CN)[
• When LPG signal is turned on, position feedback signal is switched from motor PG to
line PG and position fully closed loop by line PG is formed.
• Line PG output pulse corresponds to reference data one-by-one. That is, one pulse
from line PG is read-in as one reference unit move.
• When line PG is used, zero-point return (homing) cannot be performed. Entering
zero-point return mode causes an error.
(6) Input signal used in station No. reference method
(a) Rotating direction selection I-DRO,DR1]
By combining DROand DR1 signals, the rotating direction at the motor shaft
(viewed from the load side) in automatic operation mode is selected as shown
below:
p_na I DR0 H L H L
ter 14-b3N',_ DRI H H L L "
Absolute Short-cut Station No. Station No. (This setting
0 mode direction increasing decreasing causes an error.)
direction direction
(Example) (Example)
0 0
Incremental (This setting _"_-' _"_-'
1 mode causesan . , 3 ',
error.) k
-- 111 --
b