3.2  Operating Procedures for Utility Functions 
3.2.19  Reset Option Module Configuration Error (Fn014)
3-48
Operating Procedure
Step Operation Result
1
Press the   Key to display the 
Utility Mode Main Menu, and then 
use the   Key or   Key to 
select Fn014.
2
Press the   Key.
The Fn014 (Reset Option Module 
Configuration Error) execution dis-
play will appear.
3
Use the   Key or   Key to 
select the Option Module for which 
to reset the alarm.
4
Press the   Key.
The detected alarm will be reset.
When processing has been com-
pleted, the status display will flash 
DONE for approximately one sec-
ond and then return to 1:BB.
5
Press the   Key.
The display will return to the Utility 
Mode Main Menu.
6
Turn the SERVOPACK power sup-
ply OFF and ON again.
The parameter settings are now 
enabled.
1:BB
FUNCTION
Fn013 :MturnLmS et
Fn014:Opt Init
Fn01B:Viblvl Init
Fn01E:S vMotOp ID
0 3 :Feedback Opt
1:BB         Opt Init
01:Command Opt
02:S afety Opt
0 3 :Feedback Opt
1:BB         Opt Init
01:Command Opt
02:S afety Opt
S tart  :[DATA]
Return:[S ET]
1:BB         Opt Init
Command Opt
Initialize
1:BB
FUNCTION
Fn013 :MturnLmS et
Fn014:Opt Init
Fn01B:ViblLvl Init
Fn01E:S vMotOp ID