MRS6036EN-ch2.fm Revised: 07-04-24 Page 9
Interface panel function
Interface panel display
Information!
Set the following parameter to "1" to allow operations only by the touch panel (prohibiting the
operations by cursor key).
Parameter: S2C301 (IF panel operation by cursor key)
0: Enable, 1: Disable
! Numeric display
Follow the operations as below to display numeric values on the panel screen.
! Input of numeric value
Follow the operations below to input numeric values.
Information!
Numeric values cannot be entered in the preset counter during playback.
Operation Explanation
1
Set the item "PANEL TYPE"
in the I/F PANEL SETUP
screen to either "Counter" or
"Preset counter".
Numeric value will be displayed in either three-digit number or six-digit
number according to the setting of indicated value.
If the indicated value exceeds the specified number of digits (three-digit
or six-digit), an asterisk "*" appears instead of numeric value.
Three-digit display: Six-digit display:
Operation Explanation
1
Set the item "PANEL TYPE"
in the I/F PANEL SETUP
screen to "Preset counter".
2
Hold down [INTERLOCK]
and touch the icon of
"Preset counter" or move
the cursor to the icon of
"Preset counter", then press
[SELECT].
Numeric values can now be entered in the Preset counter.
Three-digit display: ⇒
Six-digit display: ⇒
3
Enter numeric values with
the numeric keypad.
Numeric values in the range from -99 to 999 can be entered in the three-
digit preset counter. Numeric values in the range from -99999 to 999999
can be entered in the six-digit preset counter.
No other numeric value is unable to be set except for the possible range
of settings shown below:
<Possible range of settings>
B-variable: 0 to 255
I-variable: -32768 to 32767
Register: 0 to 65535