9.14 Numeric Key Customize Function
9-93
9.14.4 Allocation of I/O Control Instructions
In key allocation (SIM), output control instructions can be allocated to the Numeric keys that
have been allocated one of the following I/O controls with key allocation (EACH).
Function Output Control Instruction To Be Allocated
Alternate output allocation DOUT OT# (No.) ON
Momentary output allocation
Pulse output allocation PULSE OT# (No.) T = output time
Group output allocation (4-bit) DOUT OGH (No.) output value
Group output allocation (8-bit) DOUT OG# (No.) output value
Analog output allocation AOUT AO# (No.) output voltage value
Operation Explanation
1 Move the cursor to the “FUNC-
TION” of the key that has been
allocated with I/O control with
key allocation (SIM) and press
[SELECT].
The selection dialog box is shown.
Main Menu ShortCut
EDIT
DISPLAY
UTILITY
DATA
APPLI. NO.: 1
KEY ALLOCATION (EACH)
KEY
-
.
1
2
3
0
4
5
6
7
8
9
FUNCTION
INSTRUCTION
DISPLAY
MAKER
MAKER
MAKER
MAKER
MAKER
MAKER
MAKER
MAKER
ALLOCATION CONTENT
MAKER
DOUT
JOB CALL
1
WORK POSITION DISP
MAKER
INSTRUCTION
JOB CALL
DISPLAY