EasyManua.ls Logo

YASKAWA U1000 Series - Standards Compliance

YASKAWA U1000 Series
53 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
YASKAWA ELECTRIC TOBP C730600 95A U1000-Series Option PS-U10 Installation Manual 43
8 Standards Compliance
8 Standards Compliance
Section Safety
DANGER
Electrical Shock Hazard
Do not examine, connect, or disconnect wiring on an energized drive.
Before servicing, disconnect all power to the equipment and wait for the time specified on
the warning label at a minimum. The internal capacitor stays charged after the drive is
de-energized. The charge indicator LED extinguishes when the DC bus voltage decreases
below 50 Vdc. When all indicators are OFF, remove the covers before measuring for
dangerous voltages to make sure that the drive is safe.
Failure to obey will cause death or serious injury.
W ARNING
Electrical Shock Hazard
Do not operate equipment with covers removed.
Failure to obey could cause death or serious injury.
Figures in this manual can show options and drives without covers or safety shields.
Install covers and safety shields before operating the option or drive. Use the option as
shown in this manual.
Always ground the motor-side grounding terminal.
Contacting the motor case can cause death or serious injury from incorrect equipment
grounding.
TOBP_C730600_95A_2_0_E.fm 43 ペー 2023年2月13日 月曜日 午後1時8分