(3)
a.
b
c,
d.
e.
f.
g.
When automatic and manual return to refer–
ence point functions are not used
To set up the programmed work coordinate
system with workpiece as a basis without
using the reference point, proceed as
follows :
Select the reference tool and set the test
workpiece.
Position the Z-axis at the workpiece face
(reference surface) by manual operation.
Reset the current position display of Z-axis.
Then Z-axis is determined as Z–axis coordi–
nate point.
Position the X-axis at the outer surface of
the workpiece by manual operation.
Then the control executes cutting outer
surface if necessary.
Turn on MACHINE LOCK and set the dimen-
sions of the work outer surface as the cur-
rent position display of the X–axis.
Then the center is determined as X-axis
coordinate point.
Turn off MACHINE LOCK.
Move the tool to the setup point for each
axis, checking against the current position
display.
When the operations mentioned above are
proceeded correctly, tool position offset
amount for the tool will be zero.
6.6
(1)
(2)
(3)
(4)
(5)
(6)
(7)
(8)
OPERATION IN TAPE AND MEMORY MODE
Make sure that NC ALARM lamp is not illu-
minated.
If illuminated, detect and eliminate
the cause by the indication of alarm code.
Refer to 4.3.9, “AIARM CODE DISPLAY.”
Check and correct the stored offset values,
and then put the machine in the correct
start point.
Set the switches on the control station of
machine to the proper positions.
MODE SELECT switch
SINGLE BLOCK toggle switch
RAPID TRAVERSE RATE OVERRIDE
switch
MANUAL ABSOLUTE toggle switch
OPTIONAL BLOCK SKIP toggle switch
OPTIONAL STOP (MO1) toggle switch
DRY RUN toggle switch
FEEDRATE OVERRIDE & JOG FEEDRATE
switch
Set the punched tape onto the tape reader.
In MEM mode, this operation is not required.
Depress RESET key on the control station.
Then LSK will be illuminated and the memory
will be rewound.
Depress CYCLE START button to give a
Cycle Start to the system.
When the Feed Hold is required for the ma-
chine during the system operation, depress
FEED HOLD button.
If the unexpected event occurs in the system,
immediately depress EMERGENCY STOP
pushbutton.
215