EasyManua.ls Logo

yellow jacket 39830 - Common Problems and Potential Solutions

yellow jacket 39830
18 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
15
Common Problems and Potential Solution
Problem Possible Causes Possible Solutions
Model 830 cannot pull auto-
mobile A/C system into a
vacuum
Service valves on hoses not properly
installed on A/C system.
Service ball valve seals are worn.
Hoses on unit are loose or leak.
Automobile A/C system has a leak.
Check valve seals and threads and replace if
needed.
Replace valve seals and schrader core depres-
sor.
Tighten or replace hoses on unit.
High side gauge readings
above normal
Restriction in A/C system or schrader
core.
Service hose ball valve closed.
Incorrect charge amount entered in unit.
Check hose connection and fix restriction. Re-
place schrader core.
Open valve.
Recover, check scale calibration, and recharge
system.
Refrigerant not being trans-
ferred during Tank Refill.
Valve on supply tank closed.
Ball valve on blue service hose closed
or hose is constricted.
Wrong hose installed on new refrigerant
tank.
Storage tank is full.
Open Valve.
Open valve or straighten hose.
Install blue service hose on refrigerant tank.
Close valve on new supply. Disconnect service
hose.
Touch Pad will not accept
commands
Button on touch pad is stuck.
Bad Touch Pad.
Wire disconnected between touch pad
and microprocessor.
Microprocessor malfunction.
Feel for non-responsive button. If not respond-
ing, call Technical Services.
Call Technical Services.
Call Technical Services.
Call Technical Services.
Fan not running in any cycle
Loose power wire to fan.
Microprocessor malfunction.
Fan malfunction.
Locate loose fitting and reconnect.
Call Technical Services.
Call Technical Services.
Machine will not turn on
Power cord is not plugged into a 120
Volt outlet.
Circuit breaker tripped on shop power
panel.
Bad Main Power switch.
Loose wire.
Bad Transformer on microprocessor
board.
Plug into outlet.
Reset circuit breaker. If circuit breaker immedi-
ately trips, do not reset. Consult a qualified
electrician.
Call Technical Services.
Repair loose wire.
Call Technical Services.
Unit will not recover refriger-
ant from A/C system
Valves on service hoses shut.
Service hose is constricted.
Unit storage tank valve is closed.
Open valves.
Straighten hose.
Open tank valves.
Compressor not operating. Call Technical Services.
Unit will not charge refriger-
ant into vehicle
Valves on service hoses shut
Service hose is constricted
Unit storage tank valve is closed
Open valves
Straighten hose
Open tank valves
Compressor not operating Call Technical Services
Refrigerant leaking during
charge operations
Service valves on hoses not properly
installed on A/C system.
Check valve seals and threads and replace if
needed.
Service ball valve seals are worn.
Replace valve seals and schrader core de-
Hoses on unit are loose or leak. Tighten or replace hoses on unit
Automobile A/C system has a leak Find leak in A/C system and repair.

Related product manuals