YOKOGAWA AXW4A User Manual

YOKOGAWA AXW4A
12 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
ADMAG TI Series
AXG/AXW Magnetic Flowmeter
Safety Manual
IM 01E21A21-02EN
2nd Edition
IM 01E21A21-02EN
AXG/AXW Magnetic Flowmeter
Users
Manual

Other manuals for YOKOGAWA AXW4A

Question and Answer IconNeed help?

Do you have a question about the YOKOGAWA AXW4A and is the answer not in the manual?

YOKOGAWA AXW4A Specifications

General IconGeneral
TypeElectromagnetic Flowmeter
Relative Humidity5 to 95% RH (Non-condensing)
Lining MaterialPTFE
Electrode MaterialHastelloy
Repeatability\u00b10.1% of reading
Protection GradeIP67
Measurement Range0 to 10 m/s
Output Signal4-20 mA, HART
Power Supply24 VDC or 100-240 VAC
Operating Temperature-20 to +60°C
DimensionsVaries by nominal size
WeightVaries by nominal size

Summary

Introduction

Precautions Related to Protection, Safety, and Alteration of the Product

Explains safety symbols like WARNING, CAUTION, IMPORTANT, and NOTE used in the manual.

Regarding This User's Manual

Details the manual's scope, copyright, warranty, error reporting, and specification limitations.

Trademark

Lists trademarks and registered trademarks of Yokogawa Electric and other companies.

For Safe Use of Product

Provides guidance for the protection and safe use of the product and system.

Safety Instrumented Systems Installation

Scope and Purpose

Provides an overview of user responsibilities for SIS installation and operation for safety.

Using this product for an SIS Application

Details how to use the ADMAG TI Series flowmeter in SIS applications, covering safety function, accuracy, and diagnostics.

Setup

Guides on setting ranges, units, and performing calibration for SIS.

Required Parameter Setting

Lists parameters required for SIS safety level, including BRAIN/HART settings and hardware configurations.

Proof Test

Explains proof testing to verify Safety Instrumented Function works without failure, including test procedures.

Repair and Replacement

Details procedures for repair, replacement, and bypass lines for product maintenance.

Startup Time

States the product generates a valid signal within 3 seconds with a 0.1s damping constant.

Firmware Update

Notes that firmware updates are handled by YOKOGAWA and not by the user.

Reliability Data

Refers to the FMEDA report for failure rates, modes, and SIL 3 capability.

Lifetime Limits

States the expected product lifetime is 10 years, impacting reliability data validity.

Environmental Limits

Mentions environmental limits are specified in the general specifications document.

Application Limits

States application limits are in this manual; exceeding them invalidates reliability data.

Definitions and Abbreviations

Provides definitions for safety terms and lists common abbreviations used in the manual.

Related product manuals