EasyManuals Logo

YOKOGAWA UT130 Technical Information

YOKOGAWA UT130
86 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #28 background imageLoading...
Page #28 background image
3-10
<Toc> <Ind>
TI 05C01E02-01E 1st Edition : Oct. 31, 2001-00
NOTE
Changing certain setup parameter may automatically initialize the operating parameters. Therefore,
after you change the setup parameters, always check the operating parameter settings to find out if
appropriate values have been set for them. If the operating parameters have been initialized, set
them to their appropriate values.
SPH
SPL
UPR
DNR
TMU
Setup parameter setting display
IN
DP
RH
RL
Displayed when DC voltage input range code is set
AL1
AL2
HY1
HY2
Displayed for the "/AL" or "/HBA" option
PSL
ADR
BPS
PRI
STP
DLN
Displayed for the "/RS" option
SC
DR
Not displayed when CTL = ONF (on/off control)
Not displayed for heating/cooling type
DIS
EOT
Displayed for the "/EX" option
RTH
RTL
Displayed for the "/RET" option
TTU
Displayed for the "/AL/EX" of "/HBA/EX" option
B
Note: If no key is pressed for a period of 2
minutes or more while in the operating or
setup parameter setting display, the
controller automatically returns to operating
display 1.
From
Page 3-8
Operating display
To Page 3-8
Press the key
for at least 3 seconds.
(To operating display)
Press the key to
move between items.

Table of Contents

Other manuals for YOKOGAWA UT130

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the YOKOGAWA UT130 and is the answer not in the manual?

YOKOGAWA UT130 Specifications

General IconGeneral
BrandYOKOGAWA
ModelUT130
CategoryTemperature Controller
LanguageEnglish

Related product manuals