IM 05P01D31-11EN page 1/12
Contents
1. Safety Precautions
2. ModelandSufxCodes
3. How to Install
4. HardwareSpecications
5. HowtoConnectWires
6. TerminalWiringDiagrams
Introduction
ThankyouforpurchasingtheUT35A/UT32ADigitalIndicatingController.
ThisoperationguidedescribesthebasicoperationsoftheUT35A/UT32A.Theguide
shouldbeprovidedtotheenduserofthisproduct.
Be sure to read thisoperationguidebefore usingthe product in order to ensure
correct operation.
Fordetailsofeachfunction,refertotheelectronicmanual.Beforeusingtheproduct,
refertothetableofModelandSufxCodestomakesurethatthedeliveredproduct
isconsistentwiththemodelandsufxcodesyouordered.Alsomakesurethatthe
followingitemsareincludedinthepackage.
•DigitalIndicatingController(themodelyouordered) ..............................x1
• Set of Brackets ........................................................................................x1
•UnitLabel(L4502VZ) ..............................................................................x1
•TagLabel(L4502VE) ..............................................................................x1
•OperationGuide(thisdocument) ............................................................x6(A3size)
(InstallationandWiring,InitialSettings,Operations,andParameters)
l
TargetReaders
Thisguideisintendedforthefollowingpersonnel;
• Engineersresponsibleforinstallation,wiring,andmaintenanceoftheequipment.
• Personnelresponsiblefornormaldailyoperationoftheequipment.
1. Safety Precautions
Thefollowing symbolisused ontheinstrument.Itindicatesthepossibilityofinjury
to theuserordamagetotheinstrument, and signies that theuser must refer to
the user’smanualforspecial instructions. Thesamesymbol isused inthe user’s
manualonpagesthattheuserneedstoreferto,togetherwiththeterm“WARNING”
or“CAUTION.”
WARNING
Calls attention to actions or conditions that could cause serious
or fatal injury to the user, and indicates precautions that should be
taken to prevent such occurrences.
CAUTION
Calls attention to actions or conditions that could cause injury to
the user or damage to the instrument or property and indicates pre-
cautions that should be taken to prevent such occurrences.
AC
AC/DC
Theequipmentwhollyprotectedbydoubleinsulationorreinforcedinsulation.
Functionalgroundingterminals
(Donotusethisterminalasaprotectivegroundingterminal).
Note
Identiesimportantinformationrequiredtooperatetheinstrument.
n
Warning and Disclaimer
(1) YOKOGAWAmakesnowarrantiesregardingtheproductexceptthosestatedin
theWARRANTYthatisprovidedseparately.
(2) Theproductisprovidedonan"asis"basis.YOKOGAWAassumesnoliabilityto
anypersonor entityfor anyloss ordamage, director indirect,arisingfromthe
useoftheproductorfromanyunpredictabledefectoftheproduct.
n
Safety,Protection,andModicationoftheProduct
(1) Inordertoprotect thesystemcontrolled bythisproduct andtheproduct itself,
and toensuresafeoperation, observethesafety precautionsdescribed inthe
user’s manual. Useoftheinstrument in a manner notprescribed herein may
compromise the product's functions and the protection features inherent in the
device.Weassumenoliabilityforsafety,orresponsibilityfortheproduct'squality,
performanceorfunctionalityshouldusersfailtoobservetheseinstructionswhen
operatingtheproduct.
(2) Installation of protection and/or safety circuits with respect to a lightning
protector;protectiveequipmentforthesystemcontrolledbytheproductandthe
productitself;foolprooforfailsafedesignofaprocess orline usingthe system
controlledbytheproductortheproductitself;and/orthedesignandinstallation
ofotherprotectiveandsafetycircuitsaretobeappropriatelyimplementedasthe
customer deems necessary.
(3) Besuretouse thesparepartsapproved byYOKOGAWAwhenreplacing parts
orconsumables.
(4) Thisproductisnot designedormanufacturedtobe usedincriticalapplications
thatdirectlyaffect or threaten human lives. Suchapplications includenuclear
power equipment, devices using radioactivity, railway facilities, aviation
equipment, airnavigation facilities, aviation facilities,andmedical equipment.
If so used, it is the user’s responsibility to include in the system additional
equipmentanddevicesthatensurepersonnelsafety.
(5) Modicationoftheproductisstrictlyprohibited.
WARNING
l
Power Supply
Ensure that the instrument’s supply voltage matches the voltage
of the power supply before turning ON the power.
l
Do Not Use in an Explosive Atmosphere
Do not operate the instrument in locations with combustible
or explosive gases or steam. Operation in such environments
constitutes an extreme safety hazard. Use of the instrument in
environments with high concentrations of corrosive gas (H
2
S,
SO
X
, etc.) for extended periods of time may cause a failure.
l
Do Not Remove Internal Unit
The internal unit should not be removed by anyone other than
YOKOGAWA's service personnel. There are dangerous high
voltage parts inside. Additionally, do not replace the fuse by
yourself.
l
Damage to the Protective Construction
Operation of the instrument in a manner not specified in the
users manual may damage its protective construction.
CAUTION
This instrument is an EMC class A product. In a domestic environ-
ment this product may cause radio interference in which case the
user needs to take adequate measures.
2. ModelandSufxCodes
n
UT35A
[Style:S1]
Model Sufxcode
Optional
sufx
code
Description
UT35A
DigitalIndicatingController
(providedwithretransmissionoutputor15VDCloop
powersupply,2DIs,and3DOs)
(Powersupply:100-240VAC)
Type 1:
Basic
control
-0 Standard type
-1 Position proportional type
-2 Heating/coolingtype
Type 2:
Functions
0 None
1 2additionalDIs,2additionalDOs
2 5additionalDIs,5additionalDOs
Type 3: Open
networks
0 None
1
RS-485communication(Max.38.4kbps,2-wire/4-wire)
2 Ethernetcommunication(withserialgatewayfunction)
3 CC-Linkcommunication
4 PROFIBUS-DPcommunication
Displaylanguage(*1)
(Note)
-1 English
-2 German
-3 French
-4 Spanish
Casecolor(Note)
0 White(Lightgray)
1 Black(Charcoalgraylight)
Fixedcode -00 Always"-00"
Optionalsufxcodes
/LP 24VDClooppowersupply(*2)
/HA Heaterbreakalarm(*3)
/DC Powersupply24VAC/DC
/CT Coating(*4)
*1: English,German,French,andSpanishcanbedisplayedastheguidedisplay.
*2: The/LPoptioncanbespecifiedinthecombinationofType2code(anyof"0"or"1")and
Type3code(anyof"0"or"1".)
*3: The/HAoptioncanbespecifiedwhentheType1codeis“-0”or“-2”.
*4: Whenthe/CToptionisspecified,theUT35Adoesnotconformtothesafetystandards(UL
andCSA)andCEmarking.
Note:Thelastdigitofthedisplaylanguagecode(-x0)hasbeenchangedintothecasecolorcode.
n
UT32A
[Style:S1]
Model Sufxcode
Optional
sufx
code
Description
UT32A
DigitalIndicatingController(providedwithretrans-
missionoutputor15VDClooppowersupply,2DIs,
and3DOs)(Powersupply:100-240VAC)
Type 1:
Basic
control
-0 Standard type
-1 Position proportional type
-2 Heating/coolingtype
Type 2:
Functions
0 None
1
RS-485communication(Max.38.4kbps,2-wire/4-
wire)
2 2additionalDIsand2additonalDOs
Type 3:
Open networks
0 None
Displaylanguage(*1)
(Note)
-1 English
-2 German
-3 French
-4 Spanish
Casecolor(Note)
0 White(Lightgray)
1 Black(Charcoalgraylight)
Fixedcode -00 Always"-00"
Optionalsufxcodes
/LP 24VDClooppowersupply(*2)
/HA Heaterbreakalarm(*3)
/DC Powersupply24VAC/DC
/CT Coating(*4)
*1: English,German,French,andSpanishcanbedisplayedastheguidedisplay.
*2: The/LPoptioncanbespecifiedinthecombinationofType1code(anyof"-0"or"-1")
andType2code(anyof"0"or"1.")Additionally,whentheType2codeis"1",theRS-485
communicationis2-wiresystem.
*3: The/HAoptioncanbespecifiedwhentheType1codeis"-0"or"-2."
*4: Whenthe/CToptionisspecified,theUT32Adoesnotconformtothesafetystandards(UL
andCSA)andCEmarking.
Note:Thelastdigitofthedisplaylanguagecode(-x0)hasbeenchangedintothecasecolorcode.
n
Accessories (sold separately)
Thefollowingisanaccessorysoldseparately.
• LL50AParameterSettingSoftware
Model Sufxcode Description
LL50A -00 ParameterSettingSoftware
• TerminalCover
ForUT35A:ModelUTAP001;ForUT32A:ModelUTAP002
• User’sManual(A4size)
Note:User’sManualcanbedownloadedfromawebsite.
•User’sManual(CD-ROM),Model:UTAP003
Note:Containsallmanuals.
3. How to Install
n
Installation Location
The instrument should be installed in indoor locations meeting the following
conditions:
Instrumented panel
Thisinstrumentis designedtobe mounted inaninstrumentedpanel.Mountthe
instrumentinalocationwhereitsterminalswillnotinadvertentlybetouched.
Well ventilated locations
Mounttheinstrumentinwellventilatedlocationstopreventtheinstrument’sinter-
naltemperaturefromrising.
However,makesurethattheterminalportionsarenotexposedtowind.Exposure
to wind may cause the temperature sensor accuracy to deteriorate. To mount mul-
tipleindicating controllers, see theexternaldimensions/panelcutout dimensions
which follow.
If mounting otherinstruments adjacent totheinstrument, complywith
thesepanelcutoutdimensionstoprovidesufcientclearancebetweentheinstruments.
Locations with little mechanical vibration
Installtheinstrumentinalocationsubjecttolittlemechanicalvibration.
Horizontal location
Mounttheinstrumenthorizontallyandensurethatitislevel,withnoinclinationto
therightorleft.
Front panel
of controller
Keep this angle
within 30°
Rear of
controller
30°
Note
If theinstrumentismovedfroma locationwith low temperature and lowhumidity
toa placewithhightemperature andhighhumidity,orifthetemperaturechanges
rapidly, condensation will result. Moreover, inthe case of thermocouple inputs,
measurementerrorswillresult.Toavoidsuchasituation,leavetheinstrumentinthe
newenvironmentunderambientconditionsformorethan1hourpriortousingit.
Donotmounttheinstrumentinthefollowinglocations:
Outdoors
Locations subject to direct sunlight or close to a heater
Installtheinstrumentinalocationwithstabletemperaturesthatremainclosetoan
averagetemperatureof23°C.Donotmountitinlocationssubjecttodirectsunlight
orclosetoaheater.Doingsoadverselyaffectstheinstrument.
Locations with substantial amounts of oily fumes, steam, moisture, dust, or
corrosive gases
Thepresenceof oilyfumes, steam,moisture,dust,or corrosivegasesadversely
affectstheinstrument.Donotmounttheinstrumentinlocationssubjecttoanyof
thesesubstances.
• Areasnearelectromagneticeldgeneratingsources
Donotplacemagnetsortoolsthatgeneratemagnetismneartheinstrument.Ifthe
instrumentisusedinlocationsclosetoa strongelectromagneticeld generating
source,themagneticeldmaycausemeasurementerrors.
• Locationswherethedisplayisdifculttosee
TheinstrumentusesanLCDfor thedisplay unit,andthiscanbedifculttosee
fromextremelyobliqueangles.Mounttheinstrumentinalocationwhereitcanbe
seenasmuchaspossiblefromthefront.
• Areasclosetoammablearticles
Absolutelydonot placetheinstrumentdirectly onam-
mablesurfaces. Ifsuch acircumstanceisunavoidable
andtheinstrumentmustbeplacedclosetoaammable
item,provideashieldforitmadeof1.43mmthickplated
steel or 1.6 mm thick unplated steel with a space of at
least150mmbetweenitandtheinstrumentonthetop,
bottom,andsides.
Areas subject to being splashed with water
WARNING
Be sure to turn OFF the power supply to the controller before in-
stalling it on the panel to avoid an electric shock.
150 mm150 mm
150 mm
150 mm
150 mm150 mm
150 mm
150 mm
Operation
Guide
IM 05P01D31-11EN
UT35A/UT32A
Digital Indicating Controllers
Operation Guide
This operation guide describes installation, wiring, and other tasks required to make the
controller ready for operation.
2nd Edition : Jun. 2010
Installation and Wiring
n
Waste Electrical and Electronic Equipment (WEEE),
Directive 2002/96/EC
ThisisanexplanationofhowtodisposeofthisproductbasedonWasteElectrical
andElectronicEquipment(WEEE),Directive2002/96/EC.Thisdirectiveisonlyvalid
intheEU.
Marking
This product complies with the WEEE Directive (2002/96/EC)
markingrequirement.
This marking indicates that you must not discard this electrical/
electronic product in domestic household waste.
Product Category
With reference to the equipment types in the WEEE directive Annex 1, this
product is classified as a Monitoring and Control instrumentation product.
Donot disposeindomestichouseholdwaste. Whendisposing productsintheEU,
contactyourlocalYokogawaEuropeB.V.ofce.
www.yokogawa.com/ns
YOKOGAWA ELECTRIC CORPORATION
Network Solutions Business Division
2-9-32, Naka-cho Musashino-shi, Tokyo 180-8750 JAPAN
YOKOGAWA CORPORATION OF AMERICA
Head office and for product sales
2 Dart Road, Newnan, Georgia 30265, USA
YOKOGAWA EUROPE B.V.
Headquarters
Euroweg 2, 3825 HD Amersfoort, THE NETHERLANDS
All Rights Reserved, Copyright © 2010 Yokogawa Electric Corporation

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the YOKOGAWA UT35A and is the answer not in the manual?

YOKOGAWA UT35A Specifications

General IconGeneral
BrandYOKOGAWA
ModelUT35A
CategoryController
LanguageEnglish

Related product manuals