16
P5415484
No. Items Optional Function
Individual
Setting
Setting
Condition
Contents Setting
133 r2
Cooling/Heating Changeover
Temperature
×
2(1.0)
3(1.5)
4(2.5)
5(3.0)
1(0.5)
2
o
F (1.0
o
C)
3
o
F (1.5
o
C)
4
o
F (2.5
o
C)
5
o
F (3.0
o
C)
1
o
F (0.5
o
C)
134 r3 Setback Temperature Compensation
×
4(2.5)
5(3.0)
6(3.5)
7(4.0)
8(4.5)
9(5.0)
10(5.5)
1(0.5)
2(1.0)
3(1.5)
4
o
F (2.5
o
C)
5
o
F (3.0
o
C)
6
o
F (3.5
o
C)
7
o
F (4.0
o
C)
8
o
F (4.5
o
C)
9
o
F (5.0
o
C)
10
o
F (5.5
o
C)
1
o
F (0.5
o
C)
2
o
F (1.0
o
C)
3
o
F (1.5
o
C)
135 r4 Not Prepared - - Not Used (Use as 00 setting conditions)
136 r5 Not Prepared - - Not Used (Use as 00 setting conditions)
137 r6 Not Prepared - - Not Used (Use as 00 setting conditions)
138 r7 Not Prepared - - Not Used (Use as 00 setting conditions)
139 r8 Not Prepared - - Not Used (Use as 00 setting conditions)
140 r9
Wired Controller Prohibit Function
while Setback Operation
×
00
01
02
Run/Stop both Available on Wired Controller
Run/Stop both Unavailable on Wired Controller
Run Unavailable/Stop Available on Wired
Controller
141 rA Not Prepared
×
- Not Used (Use as 00 conditions)
142 rb
Minimum Cool/Heat Time for
Auto Cool/Heat Operation
×
00
01
02
03
04
05
06
07
08
09
10
11
12
Not Available
10 min.
20 min.
30 min.
40 min.
50 min.
60 min.
70 min.
80 min.
90 min.
100 min.
110 min.
120 min.

Related product manuals