MODEL
BLOWER
RANGE
(RPM)
MOTOR*
ADJUSTABLE
MOTOR PULLEY
FIXED
BLOWER PULLEY
BELTS
HP
SERVICE
FACTOR
FRAME
SIZE
EFFICIENCY
(%)
PITCH
DIA.
(IN.)
BORE
(IN.)
PITCH
DIA.
(IN.)
BORE
(IN.)
PITCH
LENGTH
(IN.)
DESIG-
NATION
QTY
BHN090 975-1220 2 1.20 56 82.0 3.4 - 4.4 7/8 6.2 1 50.3 A49 1
BHN120 860-1090 3 1.20 56 82.0 3.4 - 4.4 7/8 7.0 1 57.3 A56 1
*
All motors are 1750 RPM, have solid bases and are inherently protected. These motors can be selected to operate into their service factor because they are located in the moving air,
upstream of any heating device.
BLOWER MOTOR AND DRIVE DATA
BLOWER
SPEED,
RPM
CFM
2250 2550 3000 3400 3750
ESP BHP KW ESP BHP KW ESP BHP KW ESP BHP KW ESP BHP KW
975 0.83 1.16 1.08 0.66 1.27 1.18 0.37 1.45 1.35 0.08 1.65 1.54 - - -
1025 0.98 1.21 1.13 0.82 1.34 1.25 0.52 1.54 1.44 0.21 1.75 1.63 - - -
1070 1.12 1.32 1.23 0.95 1.46 1.36 0.67 1.68 1.57 0.37 1.89 1.76 0.07 2.11 1.97
1130 1.31 1.43 1.33 1.16 1.57 1.46 0.86 1.83 1.71 0.56 2.04 1.90 - - -
1175 1.51 1.51 1.41 1.36 1.67 1.56 1.07 1.92 1.79 0.75 2.18 2.03 - - -
1220 1.68 1.66 1.55 1.53 1.81 1.69 1.23 2.10 1.96 - - - - - -
MODEL BHN090
- (SIDE DUCT APPLICATIONS)
BLOWER
SPEED,
RPM
CFM
2250 2550 3000 3400 3750
ESP BHP KW ESP BHP KW ESP BHP KW ESP BHP KW ESP BHP KW
975 0.761.161.080.571.271.180.241.451.35------
1025 0.91 1.21 1.13 0.73 1.34 1.25 0.39 1.54 1.44 0.04 1.75 1.63 - - -
1070 1.05 1.32 1.23 0.86 1.46 1.36 0.54 1.68 1.57 0.20 1.89 1.76 - - -
1130 1.24 1.43 1.33 1.07 1.57 1.46 0.73 1.83 1.71 0.39 2.04 1.90 - - -
1175 1.44 1.51 1.41 1.27 1.67 1.56 0.94 1.92 1.79 0.58 2.18 2.03 - - -
1220 1.61 1.66 1.55 1.44 1.81 1.69 1.10 2.10 1.96 ------
MODEL BHN090
- (BOTTOM DUCT APPLICATIONS)
BLOWER PERFORMANCE
- (7-1/2 & 10 TON SUPPLY AIR)
BLOWER
SPEED,
RPM
CFM
3000 3500 4000 4500 5000
ESP BHP KW ESP BHP KW ESP BHP KW ESP BHP KW ESP BHP KW
860 1.05 1.40 1.31 0.85 1.58 1.48 0.62 1.80 1.68 0.32 2.05 1.91 - - -
915 1.23 1.55 1.45 1.05 1.76 1.64 0.80 1.98 1.85 0.51 2.23 2.08 0.22 2.48 2.31
950 1.42 1.68 1.57 1.24 1.91 1.78 1.00 2.14 2.00 0.70 2.43 2.27 0.40 2.72 2.54
1000 1.60 1.83 1.71 1.44 2.07 1.93 1.20 2.33 2.17 0.93 2.62 2.45 0.65 2.91 2.72
1050 1.80 1.98 1.84 1.65 2.25 2.10 1.42 2.55 2.37 1.14 2.86 2.67 0.85 3.17 2.96
1090 1.99 2.12 1.97 1.84 2.41 2.24 1.63 2.72 2.54 1.34 3.06 2.86 - - -
MODEL BHN120
- (SIDE DUCT APPLICATIONS)
BLOWER
SPEED,
RPM
CFM
3000 3500 4000 4500 5000
ESP BHP KW ESP BHP KW ESP BHP KW ESP BHP KW ESP BHP KW
860 0.92 1.40 1.31 0.67 1.58 1.48 0.39 1.80 1.68 0.02 2.05 1.91 - - -
915 1.10 1.55 1.45 0.87 1.76 1.64 0.57 1.98 1.85 0.21 2.23 2.08 - - -
950 1.29 1.68 1.57 1.06 1.91 1.78 0.77 2.14 2.00 0.40 2.43 2.27 0.04 2.72 2.54
1000 1.47 1.83 1.71 1.26 2.07 1.93 0.97 2.33 2.17 0.63 2.62 2.45 0.29 2.91 2.72
1050 1.67 1.98 1.84 1.47 2.25 2.10 1.19 2.55 2.37 0.84 2.86 2.67 0.49 3.17 2.96
1090 1.86 2.12 1.97 1.66 2.41 2.24 1.40 2.72 2.54 1.04 3.06 2.86 - - -
NOTES: 1. Blower performance includes a wet indoor coil and 2" filters.
2. Blower performance includes the maximum number of heat exchangers.
3. Refer to page 8 for the resistance of the unit accessories.
ESP = External Static Pressure available for the supply and return air duct sytem. All internal unit resistances have been deducted from the total static pressure of the blower.
MODEL BHN120
- (BOTTOM DUCT APPLICATIONS)
511.17-TG2Y
8 Unitary Products Group

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the York SUNLINE 2000 B1HN090 and is the answer not in the manual?

York SUNLINE 2000 B1HN090 Specifications

General IconGeneral
BrandYork
ModelSUNLINE 2000 B1HN090
CategoryHeat Pump
LanguageEnglish

Related product manuals