Johnson Controls Unitary Products 23
632151-YTG-A-1010
Multipliers for determining the performance with other indoor section.
NOTE: KW RATING IS FOR OUTDOOR AND INDOOR UNITS.
HEATING PERFORMANCE DATA
OUTDOOR UNIT MODEL NO. YZF03013(C)
INDOOR COIL MODEL NO. AHX36
AIR TEMP.
ENTERING
OUTDOOR
UNIT
AIR TEMP.
ENTERING
INDOOR
COIL
ID CFM
800 1000 1200
MBTUH KW C.O.P. MBTUH KW C.O.P. MBTUH KW C.O.P.
60
60 34.9 4.32 2.1 35.6 4.54 1.9 36.2 4.77 1.8
70 34.2 3.84 2.3 34.9 4.04 2.2 35.5 4.25 2.0
80 33.5 3.44 2.6 34.1 3.62 2.4 34.8 3.82 2.2
47
60 30.3 3.93 2.0 30.6 4.03 1.9 30.9 4.14 1.7
70 29.6 3.48 2.2 30.0 3.60 2.1 30.3 3.71 1.9
80 29.0 3.11 2.4 29.4 3.23 2.3 29.7 3.36 2.2
40
60 26.7 3.54 1.9 27.3 3.66 1.8 27.9 3.79 1.7
70 26.5 3.18 2.1 27.0 3.29 2.0 27.4 3.40 1.9
80 26.4 2.89 2.4 26.7 2.98 2.3 27.0 3.08 2.1
30
60 24.4 3.33 1.8 24.0 3.30 1.8 23.6 3.28 1.7
70 23.4 2.90 2.1 23.5 2.94 2.0 23.6 2.98 1.9
80 22.5 2.54 2.3 23.0 2.64 2.2 23.5 2.74 2.1
17
60 19.3 2.75 1.8 19.7 2.79 1.7 20.0 2.83 1.6
70 18.9 2.46 2.0 19.3 2.51 1.9 19.6 2.56 1.8
80 18.6 2.21 2.2 18.9 2.27 2.1 19.3 2.32 2.0
10
60 16.7 2.45 1.7 15.9 2.30 1.6 15.0 2.16 1.6
70 16.6 2.21 1.9 16.4 2.17 1.8 16.1 2.14 1.8
80 16.4 2.01 2.1 16.8 2.06 2.0 17.3 2.12 1.9
NOTE:
ALL CAPACITIES INCLUDE INDOOR FAN HEAT AT 1250 BTUH/1000 CFM.
Air Handler Coil
MBH KW COP
AV*36 – 0.99 1.01 0.99
MV12B FC/MC43B 1.00 0.99 1.02
MV16C FC/MC43C 1.00 0.99 1.01
Furnace Coil
MBH KW COP
T*(8,L)X*A12 FC/MC/PC37A 1.01 1.02 1.00
(Y*(8,L)C/T*8V)*A12 FC/MC/PC37A 1.00 0.97 1.04
T*(8,L)X*B12 FC/MC/PC43B 1.01 1.02 1.00
T*(8,L)X*C16 FC/MC/PC43C 0.99 0.99 1.00
T*(8,L)X*C20 FC/MC/PC43C 0.98 0.97 1.02
T*9X*B12 FC/MC/PC43B 1.01 1.02 0.99
T*9X*C16 FC/MC/PC43C 1.01 1.03 0.98
(Y*(8,L)C/T*8V)*B12 FC/MC/PC43B 1.01 0.98 1.03
(Y*(8,L)C/T*8V)*C16 FC/MC/PC43C 1.00 1.00 1.00
(Y*(8,L)C/T*8V)*C20 FC/MC/PC43C 0.99 1.01 0.98
(Y*9C/T*9V)*B12 FC/MC/PC43B 1.01 0.97 1.04
(Y*9C/T*9V)*C16 FC/MC/PC43C 1.01 0.98 1.03
(Y*9C/T*9V)*C20 FC/MC/PC43C 1.00 0.99 1.02