COOLING CAPACITY - With High Efficiency Motor Furnaces
UNIT
MODEL
FURNACE
MODEL
COIL
MODEL
1
W
COOLING
STAGE
RATED
CFM
NET MBH
SEER EER
TOTAL SENSIBLE
1 PH HP WITH HIGH EFFICIENCY FURNACES
2
YZF06013(C)
T*(8,L)X*C16 FC/MC62D 21
1 1115 46.5 29.8
15.00
20.80
2 1610 55.5 39.0 11.65
T*9X*C16 FC/MC62D 21
1 1085 46.5 29.8
15.00
20.80
2 1550 55.5 39.0 11.60
T*9X*C20 FC/MC62D 21
1 1220 47.5 31.2
15.00
20.35
2 1595 55.5 38.5 11.70
T*9X*D20 FC/MC62D 24
1 1240 48.0 31.4
15.00
20.50
2 1610 55.0 38.5 11.50
(Y*(8,L)C/T*8V)*C16 FC/MC62D 21
1 1025 46.5 29.8
15.00
20.80
2 1635 55.5 38.5 11.45
(Y*(8,L)C/T*8V)*C20 FC/MC62D 21
1 1060 46.5 29.8
15.00
20.80
2 1620 55.5 39.0 11.60
(Y*9C/T*9V)*C16 FC/MC62D 21
1 1040 46.5 29.8
15.00
20.80
2 1590 55.5 38.5 11.40
(Y*9C/T*9V)*C20 FC/MC62D 21
1 1040 46.5 29.8
15.00
20.80
2 1655 55.0 38.5 11.25
(Y*9C/T*9V)*D20 FC/MC62D 24
1 1085 46.5 29.8
15.00
20.80
2 1630 55.5 38.5 11.35
T*(8,L)X*C16 FC64D 21
1 1115 48.0 31.2
15.00
21.60
2 1610 57.0 40.0 11.90
T*(8,L)X*C20 FC64D 21
1 835 45.0 28.0
15.00
20.35
2 1665 57.5 40.5 12.00
T*9X*C16 FC64D 21
1 1085 48.0 31.2
15.00
21.60
2 1550 57.0 40.0 11.85
T*9X*C20 FC64D 21
1 1220 49.5 32.6
15.00
21.10
2 1595 57.0 40.0 12.00
T*9X*D20 FC64D 24
1 1240 49.5 32.8
15.00
21.25
2 1610 57.0 40.0 11.85
(Y*(8,L)C/T*8V)*C16 FC64D 21
1 1025 48.0 31.2
15.00
21.60
2 1635 57.0 40.0 11.75
(Y*(8,L)C/T*8V)*C20 FC64D 21
1 1060 48.0 31.2
15.00
21.60
2 1630 57.0 40.0 11.85
(Y*9C/T*9V)*C16 FC64D 21
1 1040 48.0 31.2
15.00
21.60
2 1590 57.0 40.0 11.70
(Y*9C/T*9V)*C20 FC64D 21
1 1040 48.0 31.2
15.00
21.60
2 1655 56.5 40.0 11.50
(Y*9C/T*9V)*D20 FC64D 24
1 1085 48.0 31.2
15.00
21.60
2 1630 57.0 40.0 11.65
1. MC coils available with a factory installed horizontal drain pan. See price pages for specific model number.
2. Variable speed furnaces have B.O.D (Blower on Delay) standard.