8. ACCESSORIES
8.1 FUEL FILL STATION ASSEMBLY
The Diesel fuel fill station assembly is mounted on the side of the unit. This assembly contains a Protecto-Seal cap, an
electrically operated fuel level gauge with “push-to-check” switch and a level gauge to indicate fuel quantity available in
the tank.
FUEL FILL STATION ASSEMBLY
The Diesel fuel should be used this unit should content with less than 0.5% Sulphur and not to be mixed with petrol. For
the purpose of low ambient, add an appropriate amount of Kerosene prior to fill with Diesel. Refer Generator Engine
manual for more information.
NOTE:
Checking the fuel level is advised to be done only when the generator engine is not running or in “stand-by” mode. If in
case the generator engine is running and the operator decides to check the fuel level, the generator controls may stop the
engine if the “push-to-check” switch is not pressed properly.
8.2 SERVICE LAMPS
Two 60watts/220 volt service lamps are provided in the unit located in the supply fan motor section and in the generator
engine section.
8.3 ROTARY (BEACON) LAMP
A rotary lamp is fixed on top of the equipment for the purpose of providing the operator a warning signal when the
generator fuel has reached to a critical level. At 30% (preset) fuel level, this lamp will be switched “ON” as a low fuel
warning while the equipment is in continuous operation. When fuel level reaches 10%, then the equipment shuts down.
This lamp may also be switched “ON” manually through the toggle switch on the equipment’s main control panel.