EasyManuals Logo

Zapi COMBI AC0 User Manual

Zapi COMBI AC0
79 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #36 background imageLoading...
Page #36 background image
Page - 36/79 AF6ZP0AL - COMBIAC0 & ACE0 - User Manual
- EX.HYDRO: it drives the contactor for a hydraulic steering function when
the exclusive hydro input is active
- FREE: it is not used.
8) QUICK INVERSION
It can be set:
- NONE: The quick inversion function is not managed (no effect when
CNA#7 switches over).
- TIMED: The quick inversion function is timed.
- BELLY: The quick inversion function is managed but not timed.
9) SET MOTOR TEMPERATURE
It can be set:
- ANALOG: An analogue sensor for the control of the motor temperature
is connected to CNA#22. Typically the temperature sensor is a PTC
(positive thermal coefficient resistance), providing the sensor
characteristic to Zapi the correct table can be loaded in the controller
software.
- DIGITAL: A digital (on/off) sensor for the motor temperature monitoring
is connected to CNA#22 input.
- NONE: No temperature sensor is connected.
10) EV1 / 5
PRESENT/ABSENT: If set = PRESENT the diagnosis “EV1 / 5 DRIVER
SHORTED” relative to the load connected to CNA#9 or CNA#8 is activated.
When set = ABSENT the diagnosis is not implemented.
11) EV2
PRESENT/ABSENT: If set = PRESENT the diagnosis “EV2 DRIVER
SHORTED” relative to the load connected to CNA#11 is activated. When set
= ABSENT the diagnosis is not implemented.
12) EV3
PRESENT/ABSENT: If set = PRESENT the diagnosis “EV3 DRIVER
SHORTED” relative to the load connected to CNA#33 is activated. When set
= ABSENT the diagnosis is not implemented.
13) EV4
PRESENT/ABSENT: If set = PRESENT the diagnosis “EV4 DRIVER
SHORTED” relative to the load connected to CNA#34 is activated. When set
= ABSENT the diagnosis is not implemented.
14) DIAG. PEDAL WIRE KO
PRESENT/ABSENT: If set = PRESENT the diagnosis “PEDAL WIRE KO”,
relative to the connection of the two supply ends ( +12V, CNA#25; NPOT,
CNA#30) of the potentiometer in the accelerator , is activated. When set =
ABSENT the diagnosis is not implemented.
15) INVERSION MODE
ON/OFF: This parameter sets the logic of the Quick Inversion input. If set =
ON, the Quick Inversion switch is Normally Closed (function active when
switch opens). If set = OFF, the Quick Inversion switch is Normally Open
(function active when switch closes).

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Zapi COMBI AC0 and is the answer not in the manual?

Zapi COMBI AC0 Specifications

General IconGeneral
BrandZapi
ModelCOMBI AC0
CategoryInverter
LanguageEnglish

Related product manuals