EasyManuals Logo

Zapi COMBI AC0 User Manual

Zapi COMBI AC0
79 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #40 background imageLoading...
Page #40 background image
Page - 40/79 AF6ZP0AL - COMBIAC0 & ACE0 - User Manual
position.
14) MAX LOWER
%. This parameter stores the maximum voltage of lifting potentiometer output
connected to CNA#30. The min value acquisition is done closing the
DESCENT SW (DI1) and bringing the potentiometer in its min output
position.
15) PWM CHOP. START
%. This parameter stores the PWM value applied to MC coil and AUX COIL
for the first second of the output activation. It is expressed in percentage of
battery voltage.
16) PWM CHOP. WORK
%. This parameter stores the PWM value applied to MC coil and AUX COIL
after the first second of the output activation. It is expressed in percentage of
battery voltage.
17) PWM ON MAIN CONT
- OFF: the inverter applies the battery voltage to the loads on the main
contactor coil connected to CNA#12.
- ON: the PWM reduces the voltage on the main contactor coil down to the
value programmed with “PWM CHOP. START” and “PWM CHOP.
WORK” parameters.
18) PWM ON AUX OUT
- OFF: the inverter applies the battery voltage to the loads on the auxiliary
output coil connected to CAN#4.
- ON: the PWM reduces the voltage on the main contactor coil down to the
value programmed with “PWM CHOP. START” and “PWM CHOP.
WORK” parameters.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Zapi COMBI AC0 and is the answer not in the manual?

Zapi COMBI AC0 Specifications

General IconGeneral
BrandZapi
ModelCOMBI AC0
CategoryInverter
LanguageEnglish

Related product manuals