EasyManuals Logo

Zapi COMBI AC0 User Manual

Zapi COMBI AC0
79 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #68 background imageLoading...
Page #68 background image
Page - 68/79 AF6ZP0AL - COMBIAC0 & ACE0 - User Manual
32) “EMERGENCY”
Cause:
The voltage on A3 is different than +Vbatt.
Troubleshooting:
- If A3 is correctly connected to +Vbatt.
- If the fuse on A3 is not damaged.
33) “FLASH CHECKSUM”
Cause:
The software was not correctly written into the flash memory or the flash
memory is damaged.
Troubleshooting:
This type of fault is not related to external components, replace the controller.
34) “CURRENT SENS. KO”
Cause:
One of the current sensor, used to measure the value of the current on the
motor phases, is damaged.
Troubleshooting:
This type of fault is not related to external components, replace the controller.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Zapi COMBI AC0 and is the answer not in the manual?

Zapi COMBI AC0 Specifications

General IconGeneral
BrandZapi
ModelCOMBI AC0
CategoryInverter
LanguageEnglish

Related product manuals