5 CONFIGURATION FUNCTION
Using the CONFIG MENU of the programming console, the user can configure the
following functions:
SUBMENU "SET OPTIONS":
1. HOUR COUNTER:
- RUNNING: the hour counter is active only when running.
- KEYON: the hour counter is active when the key is ON.
2. BATTERY CHECK:
- ON: the battery charge is continuosly monitored .
- OFF: the battery test is not carried out.
3. QUICK INVERSION:
- FREE: the IR is active in standby, it has no timeout and finishes
only when the operator switches all the input signals off;
- HANDLE: the IR finishes after a timeout; the chopper starts again
only when the operator switches all the input signals off.
4. CURVE BRAKING:
- ON: when the RV1 is held ACTIVE during running, the new
speed is reached by braking with an intensity established
by the CURVE BRAKING parameter (see 4.2).
- OFF: the new speed is reached with a deceleration whose
intensity is established by the SPEED LIMIT BRAKING
parameter (see 5.2).
5. SAFETY SWITCH:
- NONE: the safety switch is not present.
- HANDLE: a tiller is present.
- SEAT: a seat switch is present.
6. DIR. SELECTOR:
- NONE: double pedal (one for forward direction, the other one for
backward direction).
- PRESENT: running selector + single pedal.
7. ANTI ROLL-BACK:
- ON: when left on a ramp without a running request the ma-
chine does not roll-down.
- OFF: this function is not activated.
8. TRANSPALLET MODE:
- ON: in this mode the acceleration and braking ramps are faster
(twice).
- OFF: standard ramps (switched for golf-car).