Page 19SEM1
5.1 ADJUSTMENT: DESCRIPTION AND PROGRAMMING INSTRUCTIONS
This functions allows fine tuning of the internal measurement of the battery voltage.
The tuning permits to compensate the possible voltage drops along the wires in order to
get the voltage value displayed on the console equal to the true voltage value of the
battery.
ADJUSTMENT operations with the console:
1) Opening display.
2) Press ROLL UP + SETUP to enter
the menu CONFIG.
3) Headline of the menu
SET MODEL (function not available) appears.
4) Press ROLL UP to select the menu ADJUSTMENT.
5) Headline of the menu ADJUSTMENT appears.
6) Press ENTER to enter the menu.
7) The first item of the menu: SET BATTERY TYPE.
8) Press the SET PARAM buttons to select the suitable
nominal battery voltage.
9) The new value appears.
10) Press ROLL UP for a new menu.
11) The ADJUST BATTERY menu appears.
12) The button SETUP increases the value shown on the
display, the button SET DOWN decreases it.
Set to the same value as measured on the battery
with a multimeter.
13) The new voltage value appears.

Related product manuals