15) SEAT SWITCH: the level of the Seat Microswitch digital entry.
ON / +VB = active entry of closed seat switch.
OFF / GND = non active entry of open seat switch.
16) EXCLUSIVE HYDRO:status of the exclusive hydro switch.
ON / +VB = active entry of closed switch.
OFF / GND = non active entry of open switch.
17) HAND BRAKE: the level of the Handbrake Microswitch.
ON / GND = active entry of Handbrake Switch (open switch).
OFF/ +VB = non active entry of microswitch (closed switch).
18) VOLTAGE BOOSTER: this is the booster of the voltage supplied to the motor in load
condition; it is expressed in a percentage of the full voltage.
19) BATTERY VOLTAGE: level of battery voltage measured at the input to the key switch.
20) COS FI: this is the cos j (real time calculated) of the motor.
21) BATTERY CURRENT: this is the battery current (not measured but calculated).
22) BATTERY CHARGE: the percentage Charge level of the battery.