protection. Replace the logic board.
6. CHECK UP NEEDED
This is a warning. It is an information for the user that the programmed time for mainte-
nance is elapsed.
7. INCORRECT START
This alarm signals an incorrect starting sequence. Possible causes:
a. running microswitch failure;
b. error in sequence made by the operator;
c. incorrect wiring;
d. if the default persists, replace the logic.
8. FORW + BACK
The test is carried out continuously. An alarm is signalled when a double running re-
quest is made simultaneously. Possible causes:
a. defective wiring;
b. running microswitch failure;
c. incorrect operation;
d. if the defect persists, replace the logic.
9. HANDBRAKE
The truck does not start because the handbrake switch is opened. Possible causes:
a. defective wiring;
b. failure of the microswitch;
c. incorrect operation of the operator;
If the defect persist , replace the logic.
10. CAPACITOR CHARGE
Follows the charging capacitor system:
When the key is switched ON, the inverter tries to charge the capacitor through a power
resistance, and check if the capacitor are charged within a timeout. If this is not true: an
alarm is signalled; the main contactor is not closed.
Possible reasons:
a) the charging resistance is opened; if it is opened.
b) The charging circuit has a failure.
c) There is a problem on the power modules.

Table of Contents

Other manuals for Zapi ZAPIMOS Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Zapi ZAPIMOS Series and is the answer not in the manual?

Zapi ZAPIMOS Series Specifications

General IconGeneral
BrandZapi
ModelZAPIMOS Series
CategoryInverter
LanguageEnglish

Related product manuals