Advanced User Information
Changing and Restoring Printer Settings
11/15/10 HC100 User Guide 61207L-002 B
PROTOCOL Set Protocol
Protocol is a type of error checking system. Depending on the selection, an
indicator may be sent from the printer to the host computer signifying that data
has been received. Select the protocol that is requested by the host computer.
Further details on protocol can be found in the ZPL II Programming Guide.
Default Value: NONE
Selections: NONE, ZEBRA, ACK_NAK
Corresponding ZPL Command: ^SC
Corresponding SGD Command: None
Located on Web Page: Serial Communications Setup
NETWORK ID Set Network ID
This parameter assigns a unique number to the printer when the printer is
operating in an RS422/485 multi-drop network environment (an external
RS422/485 adapter is required). This gives the host computer the means to
address a specific printer. This does not affect TCP/IP or IPX networks.
Default Value: 000
Range: 000 to 999
Corresponding ZPL Command: ^NI
Corresponding SGD Command: None
Located on Web Page: Serial Communications Setup
COMMUNICATIONS Set Communications Diagnostics Mode
The communication diagnostics mode is a troubleshooting tool for checking the
interconnection between the printer and the host computer. For more information,
see Communications Diagnostics Test on page 72.
Default Value: NORMAL MODE
Selections: NORMAL MODE, DIAGNOSTICS
Corresponding ZPL Command: ~JD to start, ~JE to stop
Corresponding SGD Command: None
Located on Web Page: None
CONTROL PREFIX Set Control Prefix Character
The printer looks for this two-digit hex character to indicate the start of a
ZPL/ZPL II control instruction.
Note • Do not use the same hex value for the control, format, and
delimiter character. The printer must see different characters to work
properly.
Default Value: 7E ~
Range: 00 to FF
Corresponding ZPL Command: ^CT or ~CT
Corresponding SGD Command: None
Located on Web Page: ZPL Control