172
ADJUSTMENTS 
E769 E770 E771 
CALIBRATION OF DIGITAL 
DASHBOARD TRAVEL SPEED  
The dashboard is calibrated by the 
manufacturer after its installation. Re-
calibration should be carried: 
−  when the tyres are strongly worn 
down, 
−  after installation of new tyres, 
−  after replacement of the dashboard. 
Calibration procedure 
−  Mark a lane 100m long on a suitable 
surface. 
−  Inflate tyres of the tractor to the pre-
scribed pressure (see tables of this 
operation manual). 
−  Start the engine. 
−  Put the tractor to the start of that 100m 
long lane. 
−  Push simultaneously the pushbuttons 
(A) and (B). Hold the pushbuttons de-
pressed for 7 seconds. The dashboard 
is then switched over to the calibration 
mode. A message “Start“ begins flash-
ing on the display. 
−  Push the pushbutton (B). A message 
“Stop“ begins flashing on the display. 
−  Drive off the tractor at steady speed 
approx. 10 km.h
-1
. 
−  The display shows number of impulses 
detected by the travel sensor. 
−  After passing the whole distance of 
100, stop the tractor at the marked end 
of the lane (see Fig. E769). 
−  Push the pushbutton (B). The number 
of pulses, detected by the ravel sen-
sor, will be saved into memory. The 
dashboard is calibrated and ready for 
operation.