EasyManua.ls Logo

Zhone MXK - Select Cleaning Materials; Clean a Connector; Clean a Receptacle

Zhone MXK
78 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Fiber optic maintenance and optical connections
MXK Hardware Installation Guide
61
Select cleaning materials
Materials used for cleaning Zhone Technologies equipment should be high
quality and suitable for the purpose.
Disconnect the cable end to be cleaned.
Using inert dusting gas, blow accumulated dust and debris off the
cylindrical and end-face surfaces of the connector.
Apply optical-grade isopropyl alcohol to a cleaning tissue.
Gently wipe the tissue over the cylindrical and end face surfaces of the
connector perpendicular to the cable, then fold the cloth and repeat the
operation. Always use a clean tissue. Reusing the same portion of the
tissue may result in recontamination.
Dry the connector by blowing it with inert dusting gas for two seconds,
holding the nozzle approximately inch from the end of the connector.
Recap or reconnect the connector promptly to avoid contamination.
Check for proper system function.
Optical cleaning kits are available from optical supply sources.
Clean a connector
Cleaning a connector
1 Disconnect the cable end to be cleaned.
2 Using inert dusting gas, blow accumulated dust and debris off the
cylindrical and end-face surfaces of the connector.
3 Apply optical-grade isopropyl alcohol to a cleaning tissue.
4 Gently wipe the tissue over the cylindrical and end face surfaces of the
connector perpendicular to the cable, then fold the cloth and repeat the
operation. Always use a clean tissue. Reusing the same portion of the
tissue may result in recontamination.
5 Dry the connector by blowing it with inert dusting gas for two seconds,
holding the nozzle approximately inch from the end of the connector.
6 Recap or reconnect the connector promptly to avoid contamination.
Check for proper system function.
Clean a receptacle
Cleaning a receptacle
Clean the optical ports on modules only if there is evidence of contamination
or reduced performance. To minimize contamination and cleaning, keep all
optical ports securely covered with a connector or a dust cap.

Table of Contents