34
Quick Start Installation Guide
807119 v1.08 05.23 G5 BCS Quick Start Guide
SYSTEM PRIMING 12:12 PM
The system reticulation will be primed
with mains water.
Ambient water will automatically be
dispensed from the tap.
Confirm the CO2 bottle is disconnected ?
Yes No
14.6 System priming
SECTION 14: Commissioning
• Read the on screen information.
• For sparkling models disconnect the CO
bottle or turn off the CO regulator (see
the User guide).
• Confirm on screen.
• Touch the run arrow to go to the next
screen.
• Monitor the on screen information.
SYSTEM PRIMING 12:12 PM
Hot Tank
Pause:
Sparkling Tank
Hot tank filling
Initialise tank
[Normal operation]
• Note if ‘Font’ has been selected on the drain away option (see section
14.4) and auto dispense is disabled on entry into this screen; the screen
prompts the user to dispense using the tap during the process.
14.7 Cleaning preparation
HYDROTAP CLEAN PREPARATION 12:12 PM
Step 1.
Insert cloth below filter.
Step 2.
Remove filter and refit dust cap.
• Read the on screen information.
• Place a cloth under the filter.
• Remove the filter, refit the dust cap,