40
Quick Start Installation Guide
807119 v1.08 05.23 G5 BCS Quick Start Guide
TANK FLUSH 12:12 PM
Pause:
Sparkling Tank
Cycle 1/1
Flushing sparkling
reticulation
Auto
Dispense
Hot Tank
Cycle 0/2
100.0
O
C
Dispense hot
water to empty
tank.
SAFETY ON
SECTION 14: Commissioning
EMPTY HOT TANK 12:12 PM
Press and hold to
empty tank
100.0
O
C
Dispense boiling
water using the
tap safety
feature
WARNING ! Boiling water
will be dispensed ! Check
sink area remains safe
OR
• Note For all boiling models, if after
filling the hot tank during the tank flush
process, the hot water temperature is
still above 50
0
C the tank will need to be
emptied again.
• Monitor the on screen information.
• The hot tank will cycle twice.
• The sparkling tank will cycle once
on both the chilled and sparkling
reticulation.
INSTALL CO2 BOTTLE 12:12 PM
Connect and turn on CO2 bottle.
Set pressure to 300kpa / 43.5psi if not preset.
• Read the on screen information.
• Ensure that the CO cylinder is connected
and if supplied with an adjustable
regulator, set to 3.0 bar (300kPa).
• Touch the green arrow to run.
• CO life settings should be adjusted for the
size of the CO bottle connected. (see the
User guide or Online Installation and User
guide.
12:12 PMPURGE WATER WITH CO2
INFO
This process removes water from the sparkling
chamber when a new CO2 bottle is installed.
This is an automatic process that will take 30 seconds.
12:12 PURGE WATER WITH CO2
Running
Water is now being purged from the sparkling chamber.
| |
Skip
• Use the skip arrow to end the CO purge
process prematurely if all water has
been purged and only gas can be heard
coming from the tap.