SECTION 14: Commissioning
14.10 Select the booster
• Read the on screen instructions.
• Select the appropriate option.
• BCS 100 & 30 models select Booster
installed.
• All other models, Booster not installed.
EXTERNAL BOOSTER 12:12 PM
Has an external booster been installed ?
Yes
installed
No
Not installed
14.11 Safety sensor calibration (Classic boiling models only)
Optional, in cases where light recalibration is required.
Pull both levers
forward
Safety
sensor
BOILING
CHILLED
CHANGE FIL
TER
SAFE
TY
Light intensity varies from site to site,
therefore it is recommended that a
re-calibration be performed at the time of
the installation. All direct sunlight must
be shaded from the HydroTap, during the
calibration. This can be achieved by closing
any nearby curtains, blinds, etc.
• Shield the HydroTap from direct sunlight.
• In normal operating mode. Turn the
power off.
• Pull both tap levers to the forward
position.
• Turn the power on.
• The safety sensor will calibrate.
• Return the levers to the neutral
position.