INSTALLATION INSTRUCTIONS & USER MANUAL
210011 V2.02 MAY 2018 -ZIP ES
TECHNICAL SUPPORT TEL: 0345 6 005 005 EMAIL: SERVICE@ZIPINDUSTRIES .CO.UK
WWW.ZIPWATER.CO.UK
General cleaning
Plastic surfaces and fittings should only be wiped with a damp cloth. Do not use abrasive or
chlorine-based cleaning agents or solvents.
The outlet fittings (special tap aerators and shower heads) should be unscrewed and cleaned at
regular intervals.
The electrical and plumbing components should be inspected at least every 3 years by a
competent person familiar with instantaneous water heaters, to ensure proper functioning and
operational safety . Water quality should be considered when determining the frequency of
inspection.
MAINTENANCE
Note Maintenance work must only be carried out by a competent person familiar with
instantaneous water heaters.
Outlet fittings (aerator insert Fig. 5 page 13) should be unscrewed from the tap nozzle and
cleaned at regular intervals.
• Rinse the regulator with water and brush off the debris. For difficult to remove deposits,
soak in white vinegar (or a proprietary scale cleaner) for a few minutes and scrub with a
toothbrush.
• If any parts are cracked or broken, replace them. If the washer has hardened, it should be
replaced.
• With the debris cleaned out, screw the regulator back into the tap. Hand tightening should be
adequate.