EasyManuals Logo

ZKTeco F18I User Manual

ZKTeco F18I
96 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #49 background imageLoading...
Page #49 background image
Error! Use the Home tab to apply 标题 1 to the text that you want to appear
here.
- 41 -
menu.
2.4.5 Access Control Parameters
Set device control locks and related device parameters.
Lock driver time length: Device control electronic lock is in enabling
time. effective value 110 seconds)
Door sensor delay: After the door is open, delay the time to check door
sensor. If door sensor state is different from the normal state of door
sensor mode, alarm will be given off. This time is called door sensor
delay. effective value: 199 seconds)
Door sensor mode: It includes NONE, NC and NO. NONE means there
is no door sensor. NO means the door is open normally. NC means the
door is closed normally.
Door sensor alarm: When abnormal door sensor state is detected, alarm
will be given off after some time. This time is door sensor alarm.
effective value: 199 seconds)
Alarm count: When the failed press times reach the set times, alarm
signal will come out.effective value 19 times)
NC time zone: Set time zone for access control NC. Nobody can unlock
during this time zone.
NO time zone: Set time zone for access control NO. The lock is always
in enabling state during this time zone.
Whether holiday is effective: Define time zone for NO or NC. Whether
the time zone set in time zone is effective.
Notice: 1) when time zone is set for NO or NC, please set door
sensor mode as “None”, or alarm signal may come out during
time zone of NO or NC.