3
❶ Specicaons
1.1 I Descripon
A Boreal Expert lter
B Mulway valve
C Clamping ring (x2)
D O-ring (x2)
E Bent pipe
F Straight pipe
G Gasket for straight pipe
H Pressure gauge
I T-connector + gasket
J Air bleed screw
K Caps (x8)
L
Protecve cap (lling the lter)
1.2 I Technical specicaons
Model D470 D530 D650 D800 D950
Filtering area m² 0.16 0.20 0.32 0.47 0.66
Filter media
capacity on kg
Sand 0.4 - 0.8 mm 85 100 160 310 485
Thick glass 1.0 - 3.0 mm* 15 15 30 45 60
Thin glass 0.7 - 1.3 mm* 60 75 105 225 345
Flow rate (m³/h)
40 m³/h/m² 6.4 8.2 12.7 18.6 26.6
50m³/h/m² 8.0 10.2 15.8 23.3 33.2
Connecons Ø 1" 1/2 1" 1/2 1" 1/2 2" 2"
Weight kg 15 18 21 36 58
Maximum ltraon rate 50 m³/h/m²
Working pressure 0.5 - 1.4 bar (7 - 20 psi)
Test pressure 2.5 bar (36 psi)
Operang temperature range (water) 2 °C - 40 °C
* Zodiac® Crystal Clear glass granulometry