Remove the peristal c pump cover,
Place the roller holder at "10:20" by turning it clockwise,
Completely free the le� ng by keeping it stretched outwards,
Then turn the roller holder clockwise to free up the tube as far as the right  ng
Make sure that the roller holder is in the 10:20 posi on.
Insert the le ng of the new peristal c tube into its housing.
Then pass the tube into the roller holder guide.
Turn the roller holder clockwise and accompany the tube as far as the right  ng.
Re t the peristal c pump cover.

 
During winterising, it is recommended to leave the pump in clean water in order to
rinse the peristal c tube by carrying out manual priming (see §"3.4 I Priming the
peristal c pump").
Then place the roller holder at 6 o’clock to facilitate restar ng.
Remove the pH sensor from its holder and store it in its original bo le or in a container
lled with tap water.
Close o the sensor holder if necessary.