2
LIMITED WARRANTY
Manufacturer warrants, to the purchaser and subsequent owner during
the warranty period, every new product to be free from defects in material
and workmanship under normal use and service, when properly used
and maintained, for a period of three years from the date of purchase.
Proof of purchase is required. Parts that fail within the warranty period,
that inspections determine to be defective in material or workmanship,
will be repaired, replaced or remanufactured at Manufacturer's option,
provided however, that by so doing we will not be obligated to replace
an entire assembly, the entire mechanism or the complete unit. No
allowance will be made for shipping charges, damages, labor or other
charges that may occur due to product failure, repair or replacement.
This warranty does not apply to and there shall be no warranty for any
material or product that has been disassembled without prior approval of
Manufacturer, subjected to misuse, misapplication, neglect, alteration,
accident or act of nature; that has not been installed, operated or
maintained in accordance with Manufacturer's installation instructions;
that has been exposed to outside substances including but not limited
to the following: sand, gravel, cement, mud, tar, hydrocarbons,
hydrocarbon derivatives (oil, gasoline, solvents, etc.), or other abrasive
or corrosive substances, wash towels or feminine sanitary products,
etc. in all pumping applications. The warranty set out in the paragraph
above is in lieu of all other warranties expressed or implied; and we do
not authorize any representative or other person to assume for us any
other liability in connection with our products.
Contact Manufacturer at, 3649 Cane Run Road, Louisville, Kentucky
40211, Attention: Customer Service Department to obtain any needed
repair or replacement of part(s) or additional information pertaining to
our warranty.
MANUFACTURER EXPRESSLY DISCLAIMS LIABILITY FOR SPECIAL,
CONSEQUENTIAL OR INCIDENTAL DAMAGES OR BREACH OF
EXPRESSED OR IMPLIED WARRANTY; AND ANY IMPLIED WARRANTY
OF FITNESS FOR A PARTICULAR PURPOSE AND OF MERCHANTABILITY
SHALL BE LIMITED TO THE DURATION OF THE EXPRESSED WARRANTY.
Some states do not allow limitations on the duration of an implied
warranty, so the above limitation may not apply to you. Some states
do not allow the exclusion or limitation of incidental or consequential
damages, so the above limitation or exclusion may not apply to you.
This warranty gives you specic legal rights and you may also have
other rights which vary from state to state.
Do’s And Don’ts For Installing A Unit
1. DO read all installation materials supplied with the pump.
2. DO inspect unit for any visible damage caused by shipping. Contact
dealer if unit appears to be damaged.
3. DO clean all debris from the pit before installation.
4. DO install a union check valve in the discharge line. DO NOT use
a discharge pipe smaller than the recommended pump discharge
sizes.
5. DO install a lter or strainer in the water supply line before the
pump to prevent small particles from clogging the operating valve.
6. DO test the pump immediately after installation to be sure that the
system is working properly.
7. DO review all applicable local and national codes and verify that
the installation conforms to each of them.
8. DO NOT use the FLEX
®
with hot water.
9. DO NOT use the FLEX
®
to remove wastewater, sewage, efuent, or
water with debris in it.
10. DO NOT use a garden hose. Garden hose is not designed to hold
municipal pressure indenitely and could leak or burst causing
ooding. The FLEX
®
requires a permanent piping method such as
copper, PEX, or CPVC.
11. DO install the FLEX
®
pump only with a 3/4" supply line.
12. DO install a union or other quick-disconnect tting to make the
pump accessible for servicing on both the water supply and
discharge piping.
13. DO install a dedicated shut-off valve on the water supply line within
6 ft. (1.8 m) of the FLEX
®
.
Helpful Hints For Easy Installation
1. The system is designed for installation in sumps with a minimum
diameter of 18” and depth of 22”. For smaller applications, consult
factory.
2. Remove all debris from the pit before installation.
3. Be sure that the pump is screwed securely to oor joist or clamped
securely to the primary pump discharge/pipe and that the two pumps
do not interfere with each other.
4. Install a serviceable check valve in the discharge line.
5. Install a lter or strainer in the water supply line before the pump.
Size the lter/strainer properly to minimize pressure drop, while
retaining particles 0.020" (0.5 mm) in diameter and larger.
6. Test the unit immediately after installation. Refer to STEP 7 (page 4).
7. Check the oat ON/OFF levels per STEP 3 (page 3).
8. Keep the model number, date code, and installation instructions in a
convenient location for future reference.
© Copyright 2020 Zoeller
®
Co. All rights reserved.
In instances where property damages are incurred as a result of an alleged product failure, the property owner must
retain possession of the product for investigation purpose.

Related product manuals