Functions added in Version 3.0
Correcting timecode errors after the power has been turned off
17
F
Multi Track Field Recorder
When the mode of Start TC is set to RTC, turning the power off lowers the timecode precision, but this function can improve the
error to the value close to 0.2 ppm when the power has been turned off.
1. Press m.
2. Use e to select
TIMECODE
(TC)
, and press E.
3. Use e to select
Start TC
,
and press E.
Setting how timecode is initialized at startup
4. Use e to select
RTC TC
Calibration
, and press E.
5. Use e to select
Recalib.
,
and press E.
6. Use e to select
Yes
, and
press E.