ZXR102900ESeriesCongurationGuide
b.Notethechuteandwhethertherelatedwireisloosen.Ifitisloose,adjustit.
3.Cleantheswitch
Notetheclothshouldnotbetoowetandtheoperationcannotaffecttheinterface.
4.Thebackupofthealarminformation,thebackupofstatisticsinformation,thebackup
ofcongurationinformation
MaintenancePeriod
ThemaintenanceperiodofEthernetswitchisshownasT able6-1.
Table6-1MaintenancePeriodofEthernetSwitch
No.MaintenanceTestItemTestPeriod
1SwitchrunningstateDay
2
Equipmentroomtemperatureandhumiditycheck
andpowercheck
Day
3
Thetelecommunicationstatebetweenswitchand
thedevice
Day
4
Whethertherelatedserviceisnormally
implemented
Day
5OrdinaryproblemmonthlysummaryMonth
6
Ordinarymaintenanceexperiencemonthly
summary
Month
7EquipmentroomcleaningMonth
8SwitchcleaningMonth
9YearlysummaryYear
10
Monitoringroomdevicefullmaintenanceand
check
Year
6.2VirtualLineDetection
VCTappliesTDRtorealizethediagnosisoftheline.Itcandiagnosethefaultstateofthe
line,suchasOpen,Short,ImpedanceMismatchandGoodtermination.Alsoitcanuse
theexperienceformulatocalculatethelocationofthefaultline.
Usetheshowvctport<1-28>commandtochecktheVCTdetectionresultofthespecied
port.
Example1
zte(cfg)#showvctport1
CableTestResultforPort1
6-2
SJ-20120409144109-002|2012-07-02(R1.0)ZTEProprietaryandCondential

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Zte ZXR10 2910E-PS and is the answer not in the manual?

Zte ZXR10 2910E-PS Specifications

General IconGeneral
ModelZXR10 2910E-PS
CategorySwitch
PoEYes
Switching Capacity20 Gbps
Forwarding Rate14.88 Mpps
LayerLayer 2
MAC Address Table8K
VLANs4K
MTBF> 100, 000 hours
Dimensions (W x D x H)440 x 220 x 44 mm
Weight3.5 kg
Operating Temperature0°C to 45°C
Storage Temperature-40°C to 70°C
Jumbo Frame9K bytes
Power SupplyAC 100-240V, 50/60Hz
Operating Humidity10% to 90% (non-condensing)
Storage Humidity5% to 95% (non-condensing)