ZXR102900ESeriesCongurationGuide
Note:
àNomorethan4areasinonenode
àNomorethan3layersinonenode
àNomorethan3layersinonearea
àNomorethan4lowerlayeraccessportsinonenode
àNomorethan8ZESRportsinonenode
àWhentheprotocolportofZESRnodeisenabledandcongured(including
masterandslaveport,edgeport,accessport),otherservices,suchasadding
aggregationportgroup,enablingportsecurity,portratelimitandenablingloop
detectioncannotbeconguredonthisprotocolport.
ConguringZESR
TheZESRcongurationincludesthefollowingcommands:
CommandFunction
zte(cfg)#setzesrdomain<1-4>{add|delete}control-vlan<vlanId>
AddsordeletesZESRdomaincontrol
VLAN.
zte(cfg)#setzesrdomain<1-4>{add|delete}protect-instance<1-15>
AddsordeletestheMSTPinstancethat
ZESRrequirestoprotect.
zte(cfg)#setzesrdomain<1-4>{add|delete}{primary-port<1-28>|
primary-trunk<1-15>|secondary-port<1-28>|secondary-trunk
<1-15>}
Addsordeletesprimary/secondary
port/trunkoneachnode.
zte(cfg)#setzesrdomain<1-4>{add|delete}{access-port<1-28>|
access-trunk<1-15>}
AddsordeletesSMART-LINKaccess
port/trunkontheZESRringnode.
zte(cfg)#setzesrdomain<1-4>modesmart-linkSetsnodetypeasSMART-LINK.
zte(cfg)#setzesrdomain<1-4>major-levelmode{master|transit|
edge-master|edge-transit}
Setsthenodeattributeofmajor-level.
zte(cfg)#setzesrdomain<1-4>major-levelpreforward-timer<3-600>
preup-timer<0-500>linkdown-failtimer<8-500>
Setspreforward-timer,preup-timerand
linkdown-failtimerontheprimaryring.
zte(cfg)#setzesrdomain<1-4>level<1-2>segment<1-4>mode{master|
transit|edge-master|edge-transit}
Setsthenodeattributeofsecondary
ring.
zte(cfg)#setzesrdomain<1-4>level<1-2>segment<1-4>{add|
delete}{edge-port<1-28>|edge-trunk<1-15>}[notmaster|master]
Addsordeletestheedgeportofthe
secondaryring.
zte(cfg)#setzesrdomain<1-4>level<1-2>segment<1-4>
preforward-timer<3-600>preup-timer<0-500>linkdown-failtimer
<8-500>
Setspreforward-timer,preup-timerand
linkdown-failtimerofthesecondaryring.