Chapter 16 Ethernet OAM Commands
Ethernet Switch CLI Reference Guide
72
16.3 Command Examples
This example enables Ethernet OAM on port 7 and sets the mode to active.
This example performs Ethernet OAM discovery from port 7.
ethernet oam mode
<active|passive>
Specifies the OAM mode on the ports.
active: Allows the port to issue and respond to Ethernet
OAM commands.
passive: Allows the port to respond to Ethernet OAM
commands.
C13
ethernet oam remote-loopback
supported
Enables the remote loopback feature on the ports. C 13
no ethernet oam remote-
loopback supported
Disables the remote loopback feature on the ports. C 13
no ethernet oam mode Resets the OAM mode to the default value. C 13
Table 45 ethernet oam Command Summary (continued)
COMMAND DESCRIPTION M P
sysname# configure
sysname(config)# ethernet oam
sysname(config)# interface port-channel 7
sysname(config-interface)# ethernet oam
sysname(config-interface)# ethernet oam mode active
sysname(config-interface)# exit
sysname(config)# exit
sysname# show ethernet oam discovery 7
Port 7
Local client
------------
OAM configurations:
Mode : Active
Unidirectional : Not supported
Remote loopback : Not supported
Link events : Not supported
Variable retrieval: Not supported
Max. OAMPDU size : 1518
Operational status:
Link status : Down
Info. revision : 3
Parser state : Forward
Discovery state : Active Send Local