Chapter 32 Link Layer Discovery Protocol (LLDP)
GS1920 Series User’s Guide
273
ELIN Number Enter a numerical digit string, corresponding to the ELIN identifier which is used during
emergency call setup to a traditional CAMA or ISDN trunk-based PSAP. The valid length
is from 10 to 25 characters.
Add Click Add after finish entering the location information.
Cancel Click Cancel to begin entering the location information afresh.
Index This lists the index number of the location configuration. Click an index number to view
or edit the location.
Port This lists the port number of the location configuration.
Location
Coordinates
This field displays the location configuration information based on geographical
coordinates that includes longitude, latitude, altitude and datum.
Civic Address This field displays the Civic Address for the remote device using information such as
Country, State, County, City, Street, Number, ZIP code and additional information.
ELIN Number This field shows the Emergency Location Identification Number (ELIN), which is used to
identify endpoint devices when they issue emergency call services. The valid length is
from 10 to 25 characters.
Delete Check the locations that you want to remove in the Delete column, then click the Delete
button.
Cancel Click Cancel to clear the selected check boxes in the delete column.
Table 131 Advanced Application > LLDP > LLDP-MED Location
LABEL DESCRIPTION