39
Installer Set Options
24-Hour Emergency Functions
Three 24-hour emergency functions: PANIC, FIRE, and EMERGENCY can be activated by buttons on
the Control Panel. The installer can set which emergency buttons on the Control Panel are active.
ACTIVE CONTROL PANEL EMERGENCY BUTTONS
Panic Fire Emergency
Quick Arming
Quick Arming allows you to arm your system without having to enter a User Code. When you press
the STAY or AWAY button, the system will start to arm without requesting a User Code.
QUICK ARMING
OFF ON (regular setting)
Quick Bypass
Normally sensors that are open at the time the system is armed will require force bypassing by
entering your User Code. The system can be set so a User Code is not required to bypass open
sensors when the system is armed.
QUICK BYPASS
OFF (regular setting) ON
Quick Exit
The Quick Exit option allows you to start the Exit Delay while the system is armed. This allows you
to leave the premises without having to disarm and rearm the system. When the Quick Exit option is
on, a QUICK EXIT button will display on the security screen. Press the button to start the Exit Delay.
After Quick Exit, the system will fully re-arm in the mode that it was in before (Stay or Away Mode).
QUICK EXIT
OFF ON (regular setting)
Auto Un-bypass
Normally, sensors manually bypassed with the User Toolbox will automatically have their bypasses
removed when the system is disarmed. The system can be set so sensors that have been manually
bypassed will stay bypassed until the bypass is manually removed.
AUTO UN-BYPASS
OFF ON (regular setting)
Auto Stay
The Auto Stay option will change the arming mode if no one exits after arming the system in Away
Mode. When the system is armed in the Away Mode the Exit Delay will begin. With the Auto Stay
option on, if the designated exit/entry door does not open and close during the Exit Delay, the
system will arm in the Stay Mode instead of the Away Mode.
AUTO STAY
OFF ON (regular setting)

Table of Contents

Other manuals for 2gig Technologies GO!control 2GIG-CNTRL2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the 2gig Technologies GO!control 2GIG-CNTRL2 and is the answer not in the manual?

2gig Technologies GO!control 2GIG-CNTRL2 Specifications

General IconGeneral
Brand2gig Technologies
ModelGO!control 2GIG-CNTRL2
CategorySecurity System
LanguageEnglish

Related product manuals