18
8.3. Parameter Tables
All programmable parameters are listed in this section. Each parameter is
accompanied with the unit used, function number (if available) for programming via a
telephone line, description of EasyGate's behavior, setting options, setting step and
default (initialization) value.
8.3.1. Telephone Line Parameters
Type of dialing Function No.: -
Select the dialing type to be received by EasyGate from the PBX or telephone
set. EasyGate accepts only the selected type of dialing, ignoring the others.
Setting options:
DTMF -EasyGate receives tone dialing only.
Pulse -EasyGate receives pulse dialing only
Default setting: DTMF
Time to dial [s] Function No.: -
Timeout during which EasyGate waits for further digits to be dialed. It starts to
establish connection when this timeout passes.
Setting options: 1-15 s
Setting step: 1 s
Default setting: 5 s
Tone after disconnection Function No.: -
If the remote subscriber hangs up first, the EasyGate subscriber can hear the
tone selected here.
Setting options:
Busy -EasyGate transmits the busy tone upon call end.
Permanent -EasyGate transmits the permanent tone upon call end.
Default setting: Busy tone
Minimal On Hook [ms] Function No.: -
The minimum line current discontinuation that EasyGate evaluates as hang-up.
Setting options: 100-1500 ms
Setting step: 100 ms
Default setting: 500 ms
Beep after dialing end Function No.: -
Select a beep to signal the end of dialing (beginning of outgoing call
establishing).
Setting options: YES/NO
Default setting: YES
BabyCall number Function No.: -
A number to be dialed for the automatic call function. If this item is blank, the
function is disabled.
Setting options: 0-15 characters (0-9,*,#,+)
Default setting: blank

Other manuals for 2N EasyGate

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the 2N EasyGate and is the answer not in the manual?

2N EasyGate Specifications

General IconGeneral
Device typeCellular network gateway
Market positioningBusiness
Data networkGPRS, GSM
GSM bands supported850, 900, 1800, 1900 MHz
GPRS multislot class10
Input voltage12 V
Operating temperature (T-T)0 - 45 °C
Weight and Dimensions IconWeight and Dimensions
Dimensions (WxDxH)170 x 130 x 45 mm

Related product manuals