Installation manual 2N® IP Uni
•
•
•
•
•
Specifications:
Passive switch: NO and NC contacts, up to 30 V / 1 A AC/DC
Switched output:
Where the security relay is fed from the intercom, 9 to 13 V DC is available on the output
depending on the power supply (PoE: 9 V; adapter: source voltage of minus 1 V) / 400 mA
DC.
Where the security relay is fed from an external power supply, 12 V / 700 mA DC is available
on the output.
Dimensions: (56 x 31 x 24) mm
Weight: 20 g
Installation:
Install the2N
®
Security Relayonto a two-wire cable between the intercom and theelectric lock
inside the area to be secured (typically behind the door). The device is poweredand controlled
via this two-wire cable and so can be added to an existing installation. Thanksto its compact
dimensions, the device can be installed into a standard mounting box.
Connection:
Connect the2N
®
Security Relayto the intercom as follows:
To the intercom active output (OUT1)
Connect the electric lock to the2N
®
Security Relayoutput as follows:
To the switched output.
To the passive output in series with the external power supply.
The device also supports a Departure button connected between the ‘PB’ and ‘- HeliosIP/IP
Intercom’terminals. Press the Departure button to activate the output for 5 seconds.
Status signalling:
Green LED Red LED Status
blinking off Operational mode