EasyManua.ls Logo

3Com 4210 - Connecting a Redundant Power Supply

3Com 4210
43 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Switch 4210 V3.01.09 Release Notes
February 27, 2009 Page 28 of 43
z Description:
Port A still sends loopback detection packet to neighbor when global loopback detection is disabled.
LSOD06981
z First found-in version: V3.01.05
z Condition:
The device receives LACP protocol packet that not conform to the Protocol stipulated (124 bytes).
z Description:
LACP protocol Packets are discarded because packets' length check failed, and so bring on
aggregate failed.
LSOD07147
z First found-in version: V3.01.05
z Condition:
Disable loopback detection globally on device, and enable loopback detection on port A. A loop exists
on port A.
z Description:
The device still sends traps that there is a loop on port A, while correctly it should not send the trap.
LSOD07375
z First found-in version: V3.01.05
z Condition:
Send UDP packets whose destination port is 1645 or 1646 to the device.
z Description:
Each UDP packet will cause 32 bytes memory leak.
LSOD07479
z First found-in version: V3.01.05
z Condition:
To disable and then enable device's STP periodically, and the network topology changed frequently.
z Description:
The device may reboot without exception information.
LSOD07571
z First found-in version: V3.01.05
z Condition:

Other manuals for 3Com 4210

Related product manuals