Loading...
Switch 4210 V3.01.09 Release Notes
February 27, 2009 Page 31 of 43
LSOD05809
z First found-in version: V3.01.03
z Condition:
More than two devices have built cluster. Execute the command “display cluster” on one device.
z Description:
The output information has spelling mistakes.
LSOD05807
z First found-in version: V3.01.03
z Condition:
More than two devices have built cluster. Execute the command “reboot member mac-address” on
the cluster command device to reboot the cluster member.
z Description:
The cluster member can not be rebooted.
LSOD05950
z First found-in version: V3.01.03
z Condition:
Configure 802.1 x authentications, cut off the user on radius server after the user gets online.
z Description:
The “Terminate-Cause” field in the packets switch sends to radius server is not right compared the
RFC standard.
LSOD05951
z First found-in version: V3.01.03
z Condition:
Build cluster on switch, which is the command switch of the cluster, the member switches join and
rejoin the cluster frequently.
z Description:
The memory leak occurs.
LSOD05840
z First found-in version: V3.01.03
z Condition:
Configure 802.1x on switch using PEAP certificate authentication method, and also configure re-
authentication on radius server.
z Description:
The re-authentication fails.

Other manuals for 3Com 4210