EasyManua.ls Logo

3Com 4210G Series - Page 78

3Com 4210G Series
78 pages
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
6-4
The Switch 4210G switches use fixed fans. If a fixed fan failure occurs, you cannot solve the problem by
yourself. Please contact your sales agent or service engineer.
To ensure the normal operation of the switch, you need to contact the local sales agent or service
engineer as soon as possible when a fixed fan failure occurs.
Configuration System Failure
After the switch is powered on and the system is normal, the booting information will be displayed on the
configuration terminal. If the configuration system has any faults, there will not be any screen display at
the configuration terminal or the displayed characters will be totally illegible.
Troubleshooting when there is no terminal display
If there is no output information after the configuration is powered on, please check whether:
z The power supply is normal
z The console cable is properly connected
If no problems are found after the above-mentioned items have been checked, the cause may lie in the
console cable or the settings of the terminal (such as hyper terminal) parameters. Please perform the
corresponding check.
Troubleshooting when the terminal display is illegible
If there is illegible display at the configuration terminal, the cause might lie in the parameter setting error
at the terminal (such as HyperTerminal). Verify the following terminal parameter (such as hyper terminal)
settings:
z Baud rate: 19,200
z Data bits: 8
z Parity: none
z Stop bits: 1
z Flow control: none
z Terminal emulation: VT100.

Table of Contents

Other manuals for 3Com 4210G Series

Related product manuals