EasyManua.ls Logo

3M DBI-SALA XE Series - Inspection Procedure

3M DBI-SALA XE Series
33 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
16
Table 2 Inspection and Maintenance Log
Model Number (Serial Number):
Date Purchased: Date of First Use:
···
;
This product must be inspected by the user before each use. Additionally, a Competent Person other than the user
must inspect this equipment at least once each year.
···
Component Inspection Procedure
Inspection Result
Pass Fail
Harness Hardware
(Table 1)
Inspect all harness hardware for damage, including all
attachment elements, buckles, adjusters, and other elements.
Each of these items must not be damaged, broken, or distorted.
Each item must also be free of any sharp edges, burrs, cracks,
worn parts, or corrosion. PVC-coated hardware must be free
of cuts, rips, tears, and holes in the coating to ensure non-
conductivity. Ensure all buckles and adjusters operate smoothly.
Webbing & Stitching
(Figure 15)
Inspect the webbing of the harness across all areas. All
webbing material must be free of cuts (A), fraying (B), heavy
soiling (C), and welding burns (D). Check for tears, abrasions,
PROGEXUQVGLVFRORUDWLRQDQGEURNHQ¿EHUV&KHFNIRUSXOOHG
or cut stitches. Broken stitches may indicate that the harness
has been impact loaded and must be removed from service.
Stitched Impact
Indicators
(Figure 16)
Verify all Impact Indicators are intact. Impact Indicators are
sections of webbing lapped back on themselves and secured
ZLWKDVSHFL¿FVWLWFKSDWWHUQ7KLVVWLWFKSDWWHUQLVGHVLJQHG
to release when the harness arrests a fall or is exposed to
equivalent force. If an Impact Indicator has been activated
(indicated), then the harness must be removed from service
and destroyed.
Labels (Figure 14)
All labels are present and fully legible.
Fall Protection Equipment
Additional Fall Protection equipment that is used with the
product is installed and inspected per the manufacturer
instructions.
···
;
If the product fails an inspection procedure, then the product fails overall inspection. If the product fails inspection,
remove it from service immediately. Clearly tag the product “DO NOT USE”. See Section 5 for more information.
···
Inspection Type:
User
Competent Person
Overall Inspection Result:
Pass
Fail
Inspected By: Date of Inspection:
Signature: Next Inspection Due:
···
Additional Notes:
Figure 15 - Webbing Figure 16 - Impact Indicators