Pre-Defined Setups
Six of the nine dosimeter setups are factory-dened and conform to standards
established for noise dosimetry in the United States and the European Union. It is
recommended to check your regulations prior to data collection.
OSHA HC (Hearing Conservation)
• A” Weighting • Slow response • 5 dB ER
• 90 dB CL • 80 dB Threshold
OSHA PEL (Permissible Exposure Level)
• A” Weighting • Slow response • 5 dB ER
• 90 dB CL • 90 dB Threshold
MSHA HC (Hearing Conservation)
• A” Weighting • Slow response • 5 dB ER
• 90 dB CL • 80 dB Threshold
MSHA PEL (Permissible Exposure Level)
• A” Weighting • Slow response • 5 dB ER
• 90 dB CL • 90 dB Threshold
ACGIH
• A” Weighting • Slow response • 3 dB ER
• 85 dB CL • 80 dB Threshold
200310EC (EU Directive)
• A” Weighting • Slow response • 3 dB ER
• 85 dB CL • No Threshold