UNITDOESNOTIGNITEWHENWATERGOESTHROUGHIT
Istheflowrateover0.75gpm?Seeiftheunitinitiateswhenyouincreasedemandofwater
beingdrawnthroughtheunit(e.g.ope ningupmorehotfixtures).
Checkthatthegaslineisopenandispurgedofair(p.22).
Checkthatthefilteron
thecoldwaterinletisclean(p.21).
Checkforreverseconnectionandcrossconnection(p.21).
Problemswithrecirculationsystem
o Seethatacheckvalveisinstalledbetweenthepumpdischargeandtheconnectionto
thecoldwatersupply.Amalfunctioningormissingcheckvalvewill
causecoldwaterto
backfeedintothesystem.
Ifyouusetheremotecontroller,istheremotepowerbuttonturnedon?
ChecktoseeiftheComputerboardisr eceivingpow er.Thiscanbeverifiedbyobservingthe
computerboardredLED.
o Ifitisnotlit,thecomputerboardisnotbeingpowered.Checktosee
iftheON/OFF
switchbelowthefuseboxissettotheonposition,orifthefuseinthefuseboxis
blown.
Ifthefandoesnotinitiateatallanditisverifiedthattheunitispowered(seeabove),theflow
sensormaynotbeworking
properly.Checktheflowsensorforproperimpellerfunctionality.
ITTAKE SALONGTIME TOGETHOTWATERATTHEFIXTURES
Thetimeittakestodeliverhotwatertoyourfixturesdependsonthelengthofpipingbetween
thetwo.Thelongerthedistance orthebiggerthepipes,thelongeritwilltaketogethotwater.
Ifthisisthecaseandyouwouldliketoreceivehot
watertoyourfixturesquicker,youmaywant
toconsiderahotwaterrecirculationsystem.
Problemswiththerecirculationsystem.
o Seethatacheckvalveisinstalledbetweenthepumpdischargeandtheconnectionto
thecoldwatersupply.Amalfunctioningormissingcheckvalvewillcausecold
waterto
backfeedintothesystem.
THEFANMOTORISSTILLSPINNINGAFTEROPERATIONHASSTOPPED
Thisisnormal.Afteroperationhasstopped,thefanmotorkeepsrunning
from5to50secondsinordertoreignitequickly,aswellaspurgeallthe
exhaustgasoutoftheflue.
ABNORMALSO UNDSCOMEFROMTHEUNIT
Checkthefanfordebris.
ContacttheTechnicalServiceDepartment.
LOSSOF PR ESSUREATALLSINKSDURINGCOMMERCIALDI SHWASHERFILLS
Verifythecapacityoftheheater(s)versustheGPMdemandofthedishwasher.
Checkthesizeofthesupplylinestothedishwasher.
Lookforawaterregulatoronthedishwasher.Checkthedishwasherratingplatetoconfirmthe
recommendedsupplywaterpressure.
Unitmaybehard
waterscaled.Scalecanreducepressureandflowofwaterthroughtheunit;
thiscanoccurasquicklyasafewmonths.