EasyManua.ls Logo

A.O. Smith 310 - TEMPERATURE FLUCTUATES WHEN A FIXTURE IS OPENED

A.O. Smith 310
32 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
TroubleshootingGuide
9|Page
Theflowadjustmentvalvecouldbeobstructedduetohardwaterscaleordebris,causinglower
thanexpectedwaterflow.Verifywaterflowwithagraduatedcontainerorwiththeremote
temperaturecontroller,ifoneisinstalled.
Theoutputthermistorcouldbecompromised.Thiscomponentmaybecheckedby
enteringthe
DiagnosticsModeonaremotecontroller,ifoneisinstalled.Turnpowerofftotheunit andrun
coldwaterthroughit;checktoseeiftheinletandoutlettemperaturesreadthesameonthe
remote.Forinstructionsonhowtodothis,refertotheMaintenance
Sheet,packagedwith
everywaterheaterandlocatedbehindthefrontpa neloftheunit.
TEMPERATUREFLUCTUATESWH ENAFIXTUREISOPENED
MakesuretheunitisinstalledproperlyusingtheProperInstallationsection(p.6)ofthisguide.
Checktheflowandtemperaturerightattheunitatthepressurereliefvalve.Iftheflowrate
andtemperaturearecorrectatthePRV,thentheproblemresideselsewhereinthe
plumbing
line.Thefollowingcouldbeplumbinglineproblems:
o Checkforcrossplumbingbetweencoldwaterlinesandhotwaterlines.Seethe
Proceduressection(p.21)forinstructions.
o Checktoseethatacheckvalveisinstalledbetweenthepumpdischargeandthe
connectiontothecold
watersupply.Inspectthecheckvalveforproperoperation.If
thereisn’toneinstalled,orifitismalfunctioning,coldwatermaybebackfeedinginto
thesystem.
o Problemswitharecirculationsystem:
Checkthatacheckvalveis installedbetweenthepumpdischargeandthe
connectiontothe
coldwatersupply.
Checktoseeifthepumpisoperatingproperly.
Checkforaircavitation.Thepumpwillbeveryhotorchattering.
Checkthedirectional indicatoronthepumpflange.
Checkthesizingofthepumpaminimumflowof2gpmis
required.
Checkgassupply
o VerifythegassupplylinesaresizedforthemaximumBtu/hdemand,asindicatedinthe
ProperInstallationsection(p.6)ofthisguide(Seethespecificationpagep.3atthe
beginningofthismanual forgasinputrating).
o ForLPmodels,theremay
notbeenoughgasleftinthepropanetank.
o Verifythatthesupplygaspressureiswithinspecification,not onlywhentheheaterisin
standby,butwhiletheheaterisrunningonmaximumfireaswell.Thismaybecaused
byamalfunctioninggassupplyregulator.
Venting
o Verifythattheexhaustventingisinstalledtomanufacturer’sspecification.
o Verifythattheventrundoesnotexceedthemaximumlimit(50ft.)
Thefilteroncoldwaterinletshouldbeclean;lookforsignsofhardwaterscaling.
Checktomakesurethatthecleartube
betweentheproportionalgasvalveandthebottomof
thecombustionchamberisconnected.
Onwellsystemsorevenonsomecitywatersystems,waterpressurefluctuations(especiallyon
lowflow)of8to10psiwillresultinflowratefluctuations,whichwillinturnresultinminor
temperaturefluctuations.
Flowsensororwatercontrolvalvemaybecompromised.ContacttheTechnicalDepartment.